PSSU/3 TAPESWITCH, PSSU/3 Datasheet

no-image

PSSU/3

Manufacturer Part Number
PSSU/3
Description
Switch, FAIL SAFE INTERFACE CONTRollerS, 110/240 VAC, WALL MOUNT
Manufacturer
TAPESWITCH
Type
Safetyr
Datasheet

Specifications of PSSU/3

Application
Medium to high risk safety
Brand/series
PSSU Series
Dimensions
4.9 in. L x 4.9 in. W x 2.9 in. H
Enclosure Type
Wall Mounted
Frequency, Operating
50⁄60 Hz
Monitor Output
5 A @ 240 VAC Resistive, Non-Inductive
Mounting Type
Wall
Output Contact
2 x Normal Open, 2A @ 240 VAC Resistive, Non-Inductive
Output Relays
2 x Safety Relays Cross Monitored
Power Consumption
6 VA
Primary Type
Controller
Protection Rating
IP67
Reset Mode
Manual (Remote)
Standards
UL, cUL
Temperature, Operating
0 to 50 °C
Time, Response
20 ms (Max.)
Voltage, Supply
110/240 VAC
Weight
13 Oz.
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Machine Control
The PSSU series of safety controllers can be used as safety devices for high-risk automation and machine control
applications. They provide the highest level of safety offered by Tapeswitch, exceeding the requirements of safety
category 3 as defined by EN-954-1f, and meeting or exceeding the safety content of the applicable OSHA, ANSI, and
RIA Standards for safety interface modules..
PSSU safety controllers have redundant safety output relays, are self-monitoring, and are rated Control Reliable, which
means that any fault in the safety-critical components will be detected and the machine will be rendered inoperative
until the fault is corrected.
These safety controllers are designed to be used with Tapeswitch low-voltage sensors such as ribbon switches, safety
mats, sensing edges, or sensing bumpers. PSSU safety interface modules are available in wall-mounted and DIN rail-
mounted versions. Other options include 24 Vdc or 110/220 Vac operation and choice of manual or auto reset.
Features & Benefits
Technical Specifications for PSSU Safety Controllers
MODEL
Supply Voltage
Mounting
Reset Mode
Output Relay
Output Contact
Rating
Applications
Safety Standard
Suitable for high-risk automation and machine control
Self-monitoring design detects faults anywhere in the safety system components
Meets or exceeds OSHA, ANSI, & RIA safety standards for safety interface modules
Automatic and manual reset versions
Wall mounting or DIN rail mounting models
DIN Rail Mounted
PSSU/1, PSSU/2
PSSU Safety Controllers (Safety Interface Modules)
110/240 VAC
50/60 Hz
PSSU/1
DIN Rail Mounting
Medium to High Risk Safety (Level of Risk Determined by Sensor)
2 x Safety Relays (force-guided contacts), Cross-monitored
Category 3: prEN 954-1 Control Reliable, Self-monitoring,
24 VDC
PSSU/2
Up to Level 2: DIN 31006-1, Level 2.2: DIN 31006,
Manual (Remote)
6 A @ 240 V, Resistive, Non-Inductive
PSSU/3, PSSU/4
Wall Mounted
Page 1 of 1
110/240 VAC
50/60 Hz
PSSU/3
UL and cUL listed
Wall Mounting
24 VDC
PSSU/4
(Click on model number to see technical manual)
110/240 VAC
DIN Rail Mounted
PSSU/A, PSSU/A2
50/60 Hz
PSSU/A
DIN Rail Mounting
Auto Reset
PSSU/A2
24 VDC

Related parts for PSSU/3

PSSU/3 Summary of contents

Page 1

... Hz Mounting DIN Rail Mounting Reset Mode Output Relay Output Contact Rating Applications Safety Standard Wall Mounted PSSU/3, PSSU/4 PSSU/2 PSSU/3 110/240 VAC 24 VDC 50/60 Hz Wall Mounting Manual (Remote Safety Relays (force-guided contacts), Cross-monitored 240 V, Resistive, Non-Inductive Medium to High Risk Safety (Level of Risk Determined by Sensor Level 2: DIN 31006-1, Level 2 ...

Page 2

... IP67 and operates from a 110 or 240 Vac supply. The PSSU/4 control unit uses the same IP67 enclosure as the PSSU/3 unit but operates from a 24 Vdc supply. Both the above units are intended to be fitted either externally or inside an existing enclosure on the machine. ...

Page 3

... When any one of the sensors is actuated the output relays de-energize. POWER CONNECTION - Connect mains power to the control unit. For AC operation on the PSSU/1 and the PSSU/3 units, jumpers will need to be fitted to select the appropriate voltage. The power consumption maximum. ...

Page 4

... Device Type Contact Type/Quantity C D Contact Rating Terminal 2 1 Numbers 5 6 Switching Frequency Monitor Output (PSSU/3 & PSSU/4 Only) Device Type Contact Type/Quantity Contact Rating Enclosure: Protection Rating PSSU/1 & PSSU/2 PSSU/3 & PSSU/4 Terminal Capacity Material MAT 2 BLACK YELLOW BLACK ...

Related keywords