D4BL-3CRB Sti (Scientific Technologies, Inc.), D4BL-3CRB Datasheet - Page 3

no-image

D4BL-3CRB

Manufacturer Part Number
D4BL-3CRB
Description
SWITCH, LOCK, SAFETY DOOR, DPDB-1 NC/1NO (slow-action) + 1NC (slow-action)
Manufacturer
Sti (Scientific Technologies, Inc.)
Type
Interlockr
Datasheet

Specifications of D4BL-3CRB

Actuator Type
Key
Contact Form
1 NO, 2 NC
Current, Rating
10 A
Dielectric Strength
25000 V
Function
Safety
Ip Rating
IP67
Mounting Hole Size
5.3 mm
Mounting Type
Door
Termination
Screw
Voltage, Rating
240 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
Use a 10-A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.
120 VAC
240 VAC
The UL/CSA approved rating for products with indicators (-A) is 6 A/115 VAC.
The above values are initial values.
The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are
sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust, oil or water
penetration, do not use the D4BL in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise
Switch damage or malfunctioning may occur.
The durability is for an ambient temperature of 5 C to 35 C and an ambient humidity of 40% to 70%.
These figures are minimum requirements for safe operation.
10 A
AC-15
3 A
250 V
IP67 (EN60947-5-1) (This applies for the Switch only. The degree of protection for the key hole is
IP00.)
Mechanical: 1,000,000 operations min.
Electrical:
0.05 to 0.5 m/s
30 operations/min max.
50/60 Hz
2 x 2 mm min.
Direct opening force: 19.61 N min. (EN60947-5-1) (See note 4.)
Direct opening travel: 20 mm min. (EN60947-5-1) (See note 4.)
All stroke:
700 N min. (GS-ET-19)
100 M
300 V (EN60947-5-1)
10 A (EN60947-5-1)
Impulse dielectric strength (U
each terminal and ground, and between each terminal and non-current-carrying metal part;
2.5 kV between solenoid and ground (EN60947-5-1)
100 A (EN60947-5-1)
3 (EN60947-5-1)
Class I (with ground terminal)
1,500 V max. (EN60947-5-1)
50 m
Malfunction: 10 to 55 Hz, 0.35-mm single amplitude
Destruction: 1,000 m/s
Malfunction: 300 m/s
Operating: –10 C to 55 C (with no icing)
Operating: 95% max.
Approx. 800 g
60 A
30 A
max. (initial value)
min. (at 500 VDC)
AC-15
6 A
115 V
500,000 operations min. (10-A resistive load at 250 VAC)
2
23 mm min.
min. (IEC68-2-27)
2
min. (IEC68-2-27)
imp
6 A
3 A
) 4 kV (EN60947-5-1) between terminals of different polarity, between
7,200 VA
Guard Lock Safety-door Switch
720 VA
D4BL
AA-77

Related parts for D4BL-3CRB