MM-SMART-40 IDEC Corporation, MM-SMART-40 Datasheet

no-image

MM-SMART-40

Manufacturer Part Number
MM-SMART-40
Description
Starter Kit, Controller; CE Approved, UL and cUL Listed
Manufacturer
IDEC Corporation
Datasheet

Specifications of MM-SMART-40

Contents
FC4A-D40K3, HMI Display & Base Module,15 W Power Supply, 26-Wire I⁄O Cable & Breakout Module, Screwdriver
Software Version
WindLDR
Standards
CE Approved, UL and cUL Listed
Kit Includes
MicroSmart PLC Slim Design, Cables and Software
Lead Free Status / Rohs Status
RoHS Compliant part
Pulse Output/Trapezoidal Control
www.idec.com
Independent dual-axis control is available with two pulse out-
puts. Locational values can be easily defined for precise posi-
tional (trapezoidal) control.
Pulse Output Function Specifications
Trapezoidal Control
(RAMP)
*Only one point of trapezoidal control is available.
Number of output points
Maximum output frequency
• Pulse output instruction
• PWM instruction
(Pulse Width Modulation control)
Steady Speed
Programmable Logic Controllers
Initial Speed
5000
CE Certified
Hz
UL Listed
File No. E211795
0
Acceleration period
2
20 kHz
USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC
Deceleration period
MicroSmart
ms
The Next Generation of PLC
Key features of the MicroSmart series include:
• 10, 16, or 24 I/O All-in-one type CPU modules with Sink/
• 20 I/O Slim type CPU modules with Sink/Source DC input
• 20 I/O Slim type CPU modules with Sink/Source DC input
• 40 I/O Slim type CPU modules with Sink/Source DC input
• DC Input, Relay Output, Transistor Output, Combination
• 24 I/O All-in-one CPU expandable to 88 I/O points; 20 I/O
• Standard RS232 port, optional plug-in RS485/RS232 port
• Optional memory cartridge or real-time clock and calendar
• Data link to other MicroSmart modules, PLCs, PCs or HG
• Approved for Class 1–Div. 2 hazardous locations (UL1604)
• Compact size
• Now available with AC input expansion module
Setting the desired values enables you to precisely man-
age the trapezoidal control
Source DC input and Relay Output
and Transistor Sink or Source Output
and Relay Output with high-speed Transistor Sink or
Source Output
and Transistor Sink or Source Output
slim types expandable up to 148 or 244 I/O; 40 I/O slim
type expandable up to 264 I/O points
cartridge
series operator interfaces
I/O and Analog I/O expansion modules available
Operation mode (S1)
Steady pulse frequency (S1 + 1)
Initial pulse frequency (S1 + 2)
Frequency change rate (S1 + 3)
Present value (S1 + 6, 7)
RAMP S1 D1
MicroSmart Series
50
10
2
1
10,000
J-3
J

Related parts for MM-SMART-40

MM-SMART-40 Summary of contents

Page 1

... Programmable Logic Controllers UL Listed File No. E211795 CE Certified Pulse Output/Trapezoidal Control Independent dual-axis control is available with two pulse out- puts. Locational values can be easily defined for precise posi- tional (trapezoidal) control. • Pulse output instruction • PWM instruction (Pulse Width Modulation control) Pulse Output Function Specifi ...

Page 2

... Programmable Logic Controllers PID Control To automatically maintain a target water temperature (PID control), use the auto tuning function to perform sampling. Based on the determined PID parameters, PID control is executed automatically. (Slim type CPU units only.) Water Temperature High alarm value 33ºC Set point 30ºC Low alarm value 27º ...

Page 3

... MIL connector type modules, see page J-10 for cables and breakout modules. 3. For specifications see page J-13 & for dimensions see page J-23. 4. For options see J-9 & for accessories see J-10. J-6 www.idec.com Programmable Logic Controllers CPU Modules - Slim Type FC4A-D20RK1 20 (12 in/ 8 out) Relay Output, 240V AC/30V DC, 2A* Sink Output 0 ...

Page 4

... Programmable Logic Controllers Part Number FC4A-N08B1 Item Input Points 8-point DC Input Type Power Voltage Terminal Removable screw terminal 1. For specifications see page J-17 & for dimensions see page J-23. 2. For options see J-9 & for accessories see J-10. 3. *For MIL connector type modules, see page J-10 for cables and breakout modules. ...

Page 5

... Relay Output FC4A-R161 0 Relay Output FC4A-R161 0 Total 46 J-8 www.idec.com Programmable Logic Controllers Combination I/O Modules - 2 Types FC4A-M24BR2 24 (16 in/ 8 out) Relay Output, 240V AC/30V DC, 2A 24V DC (Sink/Source) Wire clamp terminal Analog I/O Modules - 4 Types FC4A-L03AP1 2 Analog Inputs, 1 Analog Output 2 Analog Inputs, 1 Analog Output ...

Page 6

... Mini DIN for Slim Type CPU Terminal Module 1. For specifications see page J-22. 2. *FC4A-AS62M is compatible with CPUs: FC4A-D20RK1, FC4A-D20RS1, FC4A-D40K3, and FC4A-D40S3. (See Communication & Networking Section M for more information.) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC Option Modules FC4A-PH1 ...

Page 7

... MicroSmart Series MicroSmart Options Description Item Programming cable (Loader /user mode selectable) O/I Interface Cable (MicroSmart port 1/2 RS232 to HG1B/2A) O/I Interface Cable (MicroSmart port 1/2 RS232 to HG2F/3F/4F) Modem Cable User Communication Cable RS232C/RS485 Converter J Analog Voltage Input Cables (included with slim ...

Page 8

... FC4A-C24R2) 9-point input simulator switch (Use with FC4A-C16R2) 6-point input simulator switch (Use with FC4A-C10R2) MicroSmart Users Manual Windows-based programming software for IDEC PLCs (for more information, see page J-51). Photo Not Available USB/RS232 Serial Converter www ...

Page 9

... MM-SMART-10-252 MM-SMART-16-452 HG1X MM-SMART-10-HG1B MM-SMART-16-HG1B MM-SMART-24-HG1B MM-SMART-20-HG1B HG1B MM-SMART-40-HG1B MM-SMART-16-HG2F-M MM-SMART-16-HG2F-C MM-SMART-24-HG2F-M MM-SMART-24-HG2F-C MM-SMART-20-HG2F-M MM-SMART-20-HG2F-C HG2F MM-SMART-40-HG2F-M MM-SMART-40-HG2F-C MM-SMART-24-HG3F MM-SMART-24-HG4F HG3F/4F J-12 www.idec.com Programmable Logic Controllers MicroSmart Packages Screwdriver Breakout Module 15w Power Supply Micro Operator Smart Power Supply Interface CPU ...

Page 10

... Storage Temperature Operating Humidity Altitude Pollution Degree Corrosion Immunity Degree of Protection Grounding Wire Vibration Resistance Direct mounted 25Hz / amplitude 1.6mm 100Hz / acceleration 39.2m/s2 (4B) in each of 3 axes Shock Resistance AC 230g Weight DC 240g 1. * CPU module power consumption includes 250 mA sensor power CPU module (including 250 mA sensor power I/O modules 3. # CPU module + 7 I/O modules Communication Port 1 Specifi ...

Page 11

... Data Range 255 — — Isolated from the internal circuit RS232C Maintenance Communication, User Communication, Modem Communication Possible: RS232C or RS485 (Maintenance communication, data link) Possible Select either clock or memory cartridge Possible USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC FC4A-D20K3 ...

Page 12

... External Load for I/O Interconnection Signal Determination Method Effect of Improper Input Connection Cable Length Relay Output Specifications for CPU modules Output Points COM0 COM1 Output Points per Common COM2 COM3 Type of Output Maximum Load Current Per point Per Common Minimum Switching Load ...

Page 13

... MicroSmart Series Transistor Sink and Source Output Specifications (CPU Module) Transistor Sink and Source Output Specifications for CPU modules Output Points and Common Line Type of Output Rated Load Voltage Operating Load Voltage Range Rated Load Current Maximum Load Current ...

Page 14

... Not isolated Photocoupler isolated Not needed Static Both sinking and sourcing input signals can be connected. If any input exceeding the rated value is applied, permanent damage may be caused. 3m (9.84 ft) in compliance with electromagnetic immunity 100 times minimum 40 mA (5V DC (5V DC (24V DC (24V DC) ...

Page 15

... Programmable Logic Controllers Transistor Output Specifications (Expansion Modules) FC4A-T08K1 FC4A-T16K3 FC4A-T08S1 FC4A-T16S3 8 points (8/1 common) 16 points (16/1 common) 32 points (16/1 common) FC4A Transistor sink output FC4A Transistor source output 24V DC 20.4 to 28.8V DC 0.3A per output point 0.1A per output point (at 28.8V DC) (at 28 ...

Page 16

... Between input terminals: Not isolated Internal circuit: Photocoupler isolated Not needed Static Both sinking and sourcing input signals can be connected. If any input exceeding the rated value is applied, permanent damage may be caused. 3m (9.84 ft) in compliance with electromagnetic immunity 4 points (4/1 common) 8 points (8/2 common) 1NO 2A 7A ...

Page 17

... I/O wiring Twisted pair shielded cable recommended for improved noise immunity Photocoupler between output and internal circuit USA: (800) 262-IDEC or (408) 747-0550, Canada (888) 317-IDEC ...

Page 18

... I/O wiring Common mode reject ratio (CMRR): -50 dB Twisted pair shielded cable recommended for improved noise immunity 2 LSB maximum 500V between input and power circuit ...

Page 19

... MicroSmart Series Communication Adapter and Communication Module Specifications (Expansion Modules) Communication Adapter and Communication Module Specifications Standards Maximum Baud Rate Maintenance Communication User Communication Modem Communication Data Link Communication Maximum Cable Length Quantity of Slave Stations Isolation between Internal Circuit and ...