BH500NET American Power Conversion (APC), BH500NET Datasheet

no-image

BH500NET

Manufacturer Part Number
BH500NET
Description
APC BACK-UPS HS 500VA 120V
Manufacturer
American Power Conversion (APC)
Type
Networkr
Datasheet

Specifications of BH500NET

Brand/series
Back-UPS®
Capacity
500 VA
Color
Beige
Communication
RJ11, RJ45
Dimensions
372mmH×225mmW×105mmD
Input Type
NEMA 5-15P
Length, Cord
2.44 m
Output Type
(4) NEMA 5-15R
Power, Rating
300 W
Time, Backup
1.7 min.
Voltage, Output
120 V
Voltage, Supply
300/500 W/VA
Weight
7.42 kg
Back-UPS HS
APC BACK-UPS HS 500VA 120V
APC Back-UPS HS, 300 Watts / 500
VA,Input 120V / Output 120V
Includes: Cat6 Ethernet Cable, Cord
management straps, Documentation CD,
Installation guide, User Manual
Standard Lead Time: Usually in Stock

Related parts for BH500NET

BH500NET Summary of contents

Page 1

Back-UPS HS APC BACK-UPS HS 500VA 120V APC Back-UPS HS, 300 Watts / 500 VA,Input 120V / Output 120V Includes: Cat6 Ethernet Cable, Cord management straps, Documentation CD, Installation guide, User Manual Standard Lead Time: Usually in Stock ...

Page 2

... BH500NET Features Resettable circuit Enables a quick recovery from overload events. breakers User-replaceable Increases availability by allowing a trained user to perform upgrades and batteries replacements of the batteries reducing Mean Time to Repair (MTTR) Transformer-block Protect equipment with input transformer blocks without blocking access to spaced outlets other receptacles ...

Page 3

Output Output Power Capacity Max Configurable Power Nominal Output Voltage Output Connections Input Nominal Input Voltage Input Frequency Input Connections Cord Length Batteries & Runtime Battery Type Typical recharge time Replacement Battery RBC™ Quantity Typical Backup Time at Half Load ...

Page 4

Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with Communications & Management Control panel Audible Alarm Surge Protection and Filtering Surge energy rating Data Line Protection Physical Maximum Height Maximum Width ...

Page 5

Storage Relative Humidity Audible noise at 1 meter from surface of unit Conformance Regulatory Approvals Standard Warranty **The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full ...

Page 6

Following installation, the Back-UPS HS software is available in the Start menu. Upon launching the program, it searches for all Back-UPS HS devices on the network, and will identify them as shown in Figure Address and ...