E3X-MDA8 Omron Automation, E3X-MDA8 Datasheet - Page 7

no-image

E3X-MDA8

Manufacturer Part Number
E3X-MDA8
Description
Amplifier; Photoelectric; Dual Fiber Sensing Mode; PNP; 12 to 24 VDC; 45 mA
Manufacturer
Omron Automation
Type
Fiber Opticr
Datasheet

Specifications of E3X-MDA8

Body Style
Rectangular
Current, Consumption
45 mA
Current, Switching
50 mA
Function
Fiber Optic
Indicator
LED
Ip Rating
IP50
Material, Casing
Polybutylene Terephthalate (PBT)
Material, Cover
Polycarbonate (PC)
Mounting Type
DIN Rail
Output
PNP
Primary Type
Photoelectric
Sensing Mode
Through-Beam
Standards
CE Marked, IEC Approved
Technology
Photoelectric
Temperature, Operating
-25 to +55 °C
Termination
Connector
Time, Response
130 μs
Voltage, Supply
24 VDC
Voltage, Switching
26.4 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Amplifier Unit Connectors
Item
Digital display
Display orientation
Ambient illumination
(Receiver side)
Ambient temperature range
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
Item
Rated current
Rated voltage
Contact resistance
No. of insertions
Mate-
rials
Weight
(packed state)
Housing
Contacts
Case
Cover
Model
2.5 A
50 V
20 m
(The figure is for connection to the Amplifier Unit and the adjacent Connec-
tor. It does not include the conductor resistance of the cable.)
Destruction: 50 times
(The figure for the number of insertions is for connection to the Amplifier Unit
and the adjacent Connector.)
Polybutylene terephthalate (PBT)
Phosphor bronze/gold-plated nickel
Approx. 55 g
Model
Type
max. (20 mVDC max., 100 mA max.)
E3X-CN11/21/22
Select from incident
level + threshold or
other 7 patterns
Switching between normal/reversed display is possible.
Incandescent lamp: 10,000 lux max.
Sunlight:
Operating: Groups of 1 to 2 Amplifiers: 25 C to 55 C
Storage: 30 C to 70 C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 M
1,000 VAC at 50/60 Hz for 1 minute
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Destruction: 500 m/s
IEC 60529 IP50 (with Protective Cover attached)
Pre-wired or amplifier unit connector
Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Polybutylene terephthalate (PBT)
Polycarbonate (PC)
Instruction manual
External input models Twin-output models ATC function models Analog output models
E3X-DA@RM-S
min. (at 500 VDC)
Groups of 3 to 10 Amplifiers: 25 C to 50 C
Groups of 11 to 16 Amplifiers: 25 C to 45 C
20,000 lux max.
2
, for 3 times each in X, Y and Z directions
Select from incident level + threshold or other 6 patterns
E3X-DA@TW-S
Approx. 25 g
Advanced models
E3X-CN12
E3X-DA@AT-S
Mobile Console
Item
Applicable
Sensors
Power supply
voltage
Connection
method
Weight
(packed state)
Refer to Instruction Manual provided with
the Mobile Console for details.
E3X-DA@AN-S
Model
E3X-DA-S/MDA
E3X-DA-S
E3X-MDA
E3C-LDA
E2C-EDA
Charged with AC adapter
Connected via adapter
Approx. 580 g (Console
only: 120 g)
Select from incident
level for channel 1 +
incident level for
channel 2 or other 7
patterns
E3X-MC11-SV2
2-channe models
E3X-MDA@
7