G3TCODC24DC24 Omron Automation, G3TCODC24DC24 Datasheet - Page 11

no-image

G3TCODC24DC24

Manufacturer Part Number
G3TCODC24DC24
Description
RELAY; 18 TO 32 VDC; 18 MA (MAX.); SOLID STATE; 9 A @ 10 MS; 45 % TO 85 %
Manufacturer
Omron Automation
Type
Outputr
Datasheet

Specifications of G3TCODC24DC24

Brand/series
G3TC Series
Color
Red
Connection To Host
Board Mount
Contact Form
Solid State
Current, Input
18 mA
Current, Inrush
9 A @ 10 ms
Current, Leakage
1 mA (Max.) @ 200 VDC
Dimensions
43.2mmL×15.2mmW×31.8mmH
Humidity
45 % to 85 %
Mounting Type
PCB
Number Of Channels
1
Output
5 to 60 VDC
Output Type
Digital
Output, Range
5 to 60 VDC
Primary Type
Control
Resistance, Input
2.2 Kiloohms (Control)
Resistance, Insulation
100 Megohms (Min.) @ 500 VDC
Special Features
Photo-Coupler Isolation
Standards
UL Recognized, CSA Certified, TUV Approved, CE Marked
Temperature, Operating
-30 to +80°C (With no icing or condensation)
Voltage, Isolation
4000 VAC
Voltage, Operating
18 to 32 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
■ Operating and Storage Environments
Operating Ambient Temperature
The rated value for the ambient operating temperature of the G3TC
is for when there is no built-up heat. For this, reason, under condi-
tions where heat dissipation is not good due to poor ventilation, and
where heat may build up easily, the actual temperature of the G3TC
may exceed the rated value resulting in malfunction or burning.
When using the G3TC, design the system to allow heat dissipation
sufficient to stay below the Load Current vs. Ambient Temperature
characteristic curve. Note also that the ambient temperature of the
G3TC may increase as a result of environmental conditions (e.g., cli-
mate, air-conditioning) and operating conditions (e.g., mounting in an
airtight panel).
Operating and Storage Locations
Do not use or store the G3TC in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
1. Do not use or store in locations subject to direct sunlight.
2. Do not use in locations subject to ambient temperatures outside
3. Do not use in locations subject to relative humidity outside the
4. Do not store in locations subject to ambient temperatures outside
5. Do not use or store in locations subject to corrosive or flammable
6. Do not use or store in locations subject to dust (especially iron
7. Do not use or store in locations subject to shock or vibration.
8. Do not use or store in locations subject to exposure to water, oil,
Transportation
When transporting the G3TC, observe the following points. Not doing
so may result in damage, malfunction, or deterioration of perfor-
mance characteristics.
1. Do not drop the G3TC or subject it to severe vibrations or shock.
2. Do not transport the product if it is wet.
Vibration and Shock
Do not subject the SSR to excessive vibration or shock. Otherwise
the SSR may malfunction and internal components may be dam-
aged.
the range -30° to 80°C.
range 45% to 85% or locations subject to condensation as the
result of severe change in temperature.
the range -30° to 100°C.
gases.
dust) or salts.
or chemicals.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.