1160-02-15A E-T-A Circuit Protection and Control, 1160-02-15A Datasheet - Page 2

no-image

1160-02-15A

Manufacturer Part Number
1160-02-15A
Description
Circuit Breaker; Therm; Self-Resetting; Cur-Rtg 15A; Plug-In; 1 Pole; Vol-Rtg 12VDC
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 1160-02-15A

Actuator Type
Self-Resetting
Brand/series
1160 Series
Current, Rating
15 A
Dimensions
0.968"Lx0.39"Wx0.689"H
Mounting Type
Plug-In
Number Of Poles
1
Termination
Blade
Voltage, Rating
12 VDC
Thermal circuit breaker, with controlled self-resetting mechanism,
specially suited to installation in inaccessible locations. Under overload
conditions the circuit breaker contacts will open to protect the load
circuit. A low current excitation circuit ensures that the contacts remain
open thereby avoiding the hazards of automatic reset operation. The
circuit breaker is reset by switching off the supply circuit for a short
period. Class 2 device, contacts stay open until voltage is removed.
Type II to SAE J 553.
Automotive and marine extra low voltage wiring systems and components,
battery powered appliances.
Type No.
1160
1160 - 02 - 12A
Current rating (A)
12
15
20
30
Description
Typical applications
Ordering information
Standard current ratings and typical voltage drop values
single pole plug-in type
Design standard
02
standard version 12 V
Current ratings
12, 15, 20, 30 A
ordering example
Thermal Automotive Circuit Breaker 1160-...
Voltage drop (mV)
< 150
< 150
< 150
< 150
Voltage rating
Current ratings
Typical life
Ambient temperature
Holding current
Reset time at 23°C after
5 s of load with U
Interrupting capacity
(o-o-o)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Technical data
N
DC 12 V
12...30 A
300 operations at 2 x I
-30...+60 °C (-22...+140 °F)
< 0.6 A
< 35 sec
200 A, L/R = 2.5 ms
housing area IP54
terminal area IP00
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-3, test Ca
approx. 6 g
1160-...
N
1 - 35
1