N9010A-503 Agilent Technologies Test Equipment, N9010A-503 Datasheet

no-image

N9010A-503

Manufacturer Part Number
N9010A-503
Description
EXA SIGNAL ANALYZER, 3 GHZ
Manufacturer
Agilent Technologies Test Equipment
Type
Networkr
Datasheet

Specifications of N9010A-503

Frequency
3 GHz
Lead Free Status / Rohs Status
RoHS Exempt Product
LXI class C certified
Signal Analyzer
Agilent EXA
Data Sheet
N9010A
Available frequency range
N9010A-503
N9010A-507
N9010A-513
N9010A-526
9 kHz to 3.6 GHz
9 kHz to 7.0 GHz
9 kHz to 13.6 GHz
9 kHz to 26.5 GHz

N9010A-503 Summary of contents

Page 1

... Signal Analyzer LXI class C certified Agilent EXA N9010A Data Sheet Available frequency range N9010A-503 N9010A-507 N9010A-513 N9010A-526 9 kHz to 3.6 GHz 9 kHz to 7.0 GHz 9 kHz to 13.6 GHz 9 kHz to 26.5 GHz ...

Page 2

Table of Contents Defi nitions and Conditions . . . . . . . .3 Frequency and Time Specifi cations .4 Frequency range . . . . . . . . . . . . . . . . . ...

Page 3

Definitions and Conditions Specifi cations describe the performance of parameters covered by the product warranty and apply over °C unless otherwise noted. 95th percentile values indicate the breadth of the population (≈2σ) of performance tolerances expected to ...

Page 4

Frequency and Time Specifications Frequency range Option 503 Option 507 Option 513 Option 526 Band LO Multiple ( Frequency reference Accuracy Aging rate Temperature stability ...

Page 5

Frequency and Time Specifications Frequency span (FFT and swept mode) Range Resolution Accuracy Swept FFT Sweep time and triggering Range Accuracy Trigger Trigger delay Time gating Gate methods: Gate length range (except method = FFT): Gate delay range: Gate delay ...

Page 6

Frequency and Time Specifications 1 Analysis bandwidth Maximum bandwidth 1. Analysis bandwidth is the instantaneous bandwidth available around a center frequency over which the input signal can be digitized for further analysis or processing in the time, frequency, or modulation ...

Page 7

Amplitude Accuracy and Range Specifications Amplitude range Measurement range Input attenuator range (9 kHz to 26.5 GHz) Standard Option FSA Electronic attenuator (Option EA3) Frequency range Attenuation range Electronic attenuator range Full attenuation range (mechanical + electronic) Maximum safe input ...

Page 8

Amplitude Accuracy and Range Specifications Frequency response (10 dB input attenuation °C, preselector centering applied, σ = nominal standard deviation) Preamp on (Option P03 attenuation) Input attenuation switching uncertainty Total absolute amplitude accuracy (10 dB ...

Page 9

Amplitude Accuracy and Range Specifications Resolution bandwidth switching uncertainty (referenced to 30 kHz RBW 1.5 MHz RBW 1.6 MHz to 3 MHz RBW MHz RBW Reference level Range Log scale Linear scale Accuracy ...

Page 10

Dynamic Range Specifications 1 dB gain compression (two-tone) Preamp on (Option P03) Displayed average noise level (DANL) (Input terminated, sample or average detector, averaging type = Log input attenuation, IF Gain = High °C) Preamp ...

Page 11

Dynamic Range Specifications Second harmonic distortion (SHI) Third-order intermodulation distortion (TOI) (two -30 dBm tones at input mixer with tone separation > 5 times IF prefi lter bandwidth °C, see Specifi cations Guide for IF prefi lter ...

Page 12

Dynamic Range Specifications 1 Phase noise Noise sidebands ( ° GHz) 1. For nominal values, refer to Figure 3. Figure 3. Nominal phase noise at different center frequencies 12 (continued) Offset Specifi cation 100 Hz ...

Page 13

Power Suite Measurement Specifications Channel power Amplitude accuracy, W-CDMA or IS95 ( °C, attenuation = 10 dB) Occupied bandwidth Frequency accuracy Adjacent channel power Accuracy, W-CDMA (ACLR) (at specifi c mixer levels and ACLR ranges) MS BTS Dynamic ...

Page 14

Power Suite Measurement Specifications Burst power Methods Results Spurious emission W-CDMA (1 to 3.6 GHz) Table driven spurious signals; search across regions. Dynamic range Absolute sensitivity Spectrum emission mask (SEM) ® cdma2000 (750 kHz offset) Relative dynamic range (30 kHz ...

Page 15

General Specifications Temperature range Operating Storage EMC Complies with European EMC Directive 2004/108/EC • IEC/EN 61326-1 or IEC/EN 61326-2-1 • CISPR Pub 11 Group 1, class A • AS/NZS CISPR 11:2002 • ICES/NMB-001 This ISM device complies with Canadian ICES-001. ...

Page 16

General Specifications (continued) Power requirements Voltage and frequency (nominal) Power consumption On Standby Display Resolution Size Data storage Internal External Weight (without options) Net Shipping Dimensions Height Width Length Warranty The EXA signal analyzer is supplied with a one-year warranty. ...

Page 17

Inputs and Outputs Front panel RF input Connector Probe power Voltage/current USB 2.0 ports Master (2 ports) Standard Connector Output current Rear panel 10 MHz out Connector Output amplitude Frequency Ext Ref In Connector Input amplitude range Input frequency Frequency ...

Page 18

Inputs and Outputs (continued) Rear panel (continued) Sync (reserved for future use) Connector Monitor output Connector Format Resolution Noise source drive +28 V (pulsed) Connector SNS series noise source Digital bus (reserved for future use) Connector Anolog out Connector USB ...

Page 19

... EXA Signal Analyzer Ordering Information For further information, refer to EXA Signal Analyzer Confi guration Guide (5989-6531EN) Hardware N9010A N9010A-503 N9010A-507 N9010A-513 N9010A-526 N9010A-B25 N9010A-FSA N9010A-PFR N9010A-EA3 N9010A-P03 N9010A-PC2 N9010A-HDD N9010A-SSD Optional features N9010A-EMC Applications Note: The last two letters of ordering numbers indicate the license type. FP stands for Fixed Perpetual, TP for Transportable Perpetual recommended you confi gure each application with the license type ...

Page 20

... N9010A-UK6 N9010A-1A7 N9010A-A6J R-50C-011-3 R-50C-013-3 1. Does not fi t Option N9010A-BAG accessory pouch. Order N9010A-KB2 for accessory pouch that fi ts keyboard. 2. Options not available in all countries 20 (continued) VXA Basic VSA-Lite (required option at initial order of 89601X) VXA X-Series connectivity (required option at initial order of 89601X, requires 205) ...

Page 21

Literature Resources Literature title Agilent EXA Signal Analyzers Brochure Data Sheet Confi guration Guide Agilent MXA Signal Analyzers Brochure Data Sheet Confi guration Guide Option BBA: Analog Baseband IQ Inputs Technical Overview Agilent X-Series Signal Analyzers (MXA/EXA) Demonstration Guide X-Series ...

Page 22

Get the latest information on the products and applications you select. www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confi dence. www.agilent.com/find/open Agilent Open simplifi es the process of connecting and programming test systems to help engineers ...