XW1E-BV411M-RH-EMO IDEC Corporation, XW1E-BV411M-RH-EMO Datasheet

no-image

XW1E-BV411M-RH-EMO

Manufacturer Part Number
XW1E-BV411M-RH-EMO
Description
EMERGENCY STOP 22MM XW SERIES NON ILLUMINATED 1NO 1NC CONTACTS, SCREW TERMINALS
Manufacturer
IDEC Corporation
Type
Pushbuttonr
Datasheet

Specifications of XW1E-BV411M-RH-EMO

Actuator Type
Mushroom
Contact Form
1 NC/NO
Current, Rating
5/2 AAC/ADC
Dielectric Strength
250 V
Function
E-Stop
Mounting Hole Size
22.3 mm
Mounting Type
Panel
Operation
Push-Lock Turn-Reset
Termination
Screw
Voltage, Rating
250 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
X Series E-Stops
Key features:
Specifi cations
Applicable Standards
Operating Temperature
Operating Humidity
Storage Temperature
Operating Force
Minimum Force Required for
Direct Opening Action
Min Operator Stroke Required
for Direct Opening Action
Maximum Operator Stroke
Contact Resistance
Contact Material
Insulation Resistance
Impulse Withstand Voltage
Pollution Degree
Operation Frequency
Shock Resistance
Vibration Resistance
Mechanical Life
Electrical Life
Degree of Protection
Terminal Style
Recommended Tightening
Torque for Locking Ring
Wire Size
Weight
The depth behind the panel is only 48.7 mm for 1 to 4 contacts (with terminal cover)
for illuminated and non-illuminated units.
IDEC’s original “Safe break action” ensures that the NC contacts open when the contact
block is detached from the operator.
1 to 4NC main contacts and 1 or 2NO monitor contacts
Push-to-lock, Pull or Turn-to-reset operator
Safety lock mechanism (IEC60947-5-5, 6.2)
Degree of protection IP65 (IEC60529)
Fingersafe (IP20) terminals
Two button sizes: ø40 and ø60 mm
Push-ON illumination type available (40mm mushroom head)
Direct opening action mechanism (IEC60947-5-5, 5.2, IEC60947-5-1, Annex K)
RoHS compliant (EU directive 2002/95/EC).
UL c-UL listed. EN compliant
UL NISD category emergency stop device (File #E305148)
IEC60947-5-1, EN60947-5-1, IEC60947-5-5, EN60947-5-5, UL508, CSA C22.2 No. 14
Non-illuminated: –25 to +60°C (no freezing), Illuminated: –25 to +55°C (no freezing)
45 to 85% RH (no condensation)
–45 to +80°C
Push-to-lock: 32N
Pull-to-reset: 21N
Turn-to-reset: 0.27N·m
80N
4mm
4.5mm
50mΩ maximum (initial value)
Gold plated silver
100MΩ minimum (500V DC megger)
2.5kV
3
900 operations/hour
Operating extremes: 150m/s
Operating extremes: 10 to 500Hz, amplitude 0.35mm acceleration 50m/s
Damage limits: 10 to 500Hz, amplitude 0.35mm acceleration 50m/s
250,000 operations minimum
100,000 operations minimum, (250,000 operations minimum @ 24V AC/DC, 100mA)
Operator: IP65 (IEC60529)
Terminal: IP20 (when XW9Z-VL2MF is installed)
M3.0 screw terminal
2.0N·m
16 AWG max
ø40mm: 72g
ø60mm: 81g
2
(15G), Damage limits: 1000m/s
22mm XW E-Stops
UL File #E68961
2
(100G)
2
2
XW Series
CCC No. 2005010305150897

Related parts for XW1E-BV411M-RH-EMO

XW1E-BV411M-RH-EMO Summary of contents

Page 1

X Series E-Stops Key features: • The depth behind the panel is only 48.7 mm for contacts (with terminal cover) for illuminated and non-illuminated units. • IDEC’s original “Safe break action” ensures that the NC contacts open ...

Page 2

... X Series E-Stops Part Number 1NC XW1E-BV411M-R 2NC XW1E-BV402M-R 2NC XW1E-BV422M-R 3NC XW1E-BV413M-R 4NC XW1E-BV404M-R 1NC XW1E-BV511M-R 2NC XW1E-BV502M-R 2NC XW1E-BV522M-R 3NC XW1E-BV513M-R 4NC XW1E-BV504M-R 1NC XW1E-LV411Q4M-R 2NC XW1E-LV402Q4M-R 2NC XW1E-LV422Q4M-R 3NC XW1E-LV413Q4M-R 4NC XW1E-LV404Q4M-R 2NC XW1E-TV412Q4M-R ...

Page 3

... Panel Cutout – 0.6A 0.3A 2A 0.4A 0.2A 1A 0.22A 0.1A Part Numbers Key XW1E - Q4M - R Illumination B: Non-Illuminated L: Illuminated LED T: Illuminated Push-ON LED Mushroom Size 4: ø40mm 5: ø60mm (non-illuminated only) 2NC 1NO-1NC 2NO-2NC TOP TOP TOP * ∗3 ∗ ...

Page 4

XW Series XW Non-Illuminated (with terminal cover) Panel Thickness 0 Terminal Screw Gasket 18.5 20.1 Locking Ring 47.2 Terminal Cover 48.7 XW9Z-VL2M ø40mm Button 32 Accessories: Terminal Covers Model Description Terminal Cover for contact block IP20 Fingersafe ...

Page 5

X Series E-Stops Removing the Contact Block First unlock the operator button. Grab the bayonet ring j and pull back the bayonet ring until the latch pin clicks k, then turn the contact block counter- clockwise and pull out l. ...

Page 6

... When pressing the button, the NO monitor contacts will bounce. When designing a control circuit, take the contact bounce time into consider- ation (reference value: 20 ms). LED Illuminated Switches LED lamp is built into the contact block and cannot be replaced. Installing the Anti-rotation Ring ...

Related keywords