4184N/17X EBM-Papst Industries Inc, 4184N/17X Datasheet

no-image

4184N/17X

Manufacturer Part Number
4184N/17X
Description
Fan; DC; Brushless; 24V; 4.5W; 106 CFM; 49 dBA; Terminals; Alarm; 4100Series; 119x38mm
Manufacturer
EBM-Papst Industries Inc
Datasheet
38
119 x 38 mm (4.7" X 1.5") Brushless DC
4.69" X 4.96" X 1.50" Brushless DC, Metal housing, Plastic Impeller, Air Intake – Over Struts
DIMENSIONS
Curve
CONSTRUCTION
MOUNTING &
CONNECTION
Call ebm/Papst at 860-674-1515 • Fax 860-674-8536 • E-mail: sales@ebm.com for Technical Assistance
1
2
1
2
1
1
PART
NUMBER
4182NGX
4182NX
4184NGX
4184NX
4188NXM
4105GX
© ebm/Papst 1995, 1996, 1997. ebm/Papst reserves the right to change any specifications or data without notice
Bearing
Type of
Sleeve
Sleeve
Sleeve
Mounting:
Weight:
Housing:
Ball
Ball
Ball
Volts
DC
12
12
24
24
48
5
From either face using four
.146" (3.7 mm) holes
14 ounces (390g) except 4105GX
Metal with plastic impeller
4.5 - 5.5
12 - 30
12 - 29
36 - 56
Voltage
Range
7 - 15
7 - 15
Watts @ 0"
3.5
4.5
3.5
4.5
3.5
4.0
CFM
106
106
94
94
94
94
.50
.40
.30
.20
.10
0
dBA
44
49
44
49
44
44
* UL yellow card E38324, CSA file 27697, VDE file 8324
20
Max C (oz)
Temp. Wgt.
40
75
75
75
75
75
72
Connection:
Options:
40
14
14
14
14
14
17
80
60
Features
.110" x .02" Terminals
.110" x .02" Terminals
.110" x .02" Terminals
.110" x .02" Terminals
.110" x .02" Terminals
.110" x .02" Terminals –
Airflow CFM (cubic feet /minute)
120
Airflow cubic meters/hour
Terminals two flat pins:
.110" x .02" (2.8 x .5 mm)
Hall Effect monitor
80
SLEEVE BEARING SYSTEM
160
HIGH PERFORMANCE
SINTEC
1
100
4100 Series
2
UL CSA VDE
200
120
Approvals*
100
75
125
25
50

Related parts for 4184N/17X

4184N/17X Summary of contents

Page 1

X 1.5") Brushless DC DIMENSIONS 4.69" X 4.96" X 1.50" Brushless DC, Metal housing, Plastic Impeller, Air Intake – Over Struts PART Type of Curve NUMBER Bearing 1 4182NGX Sleeve 2 4182NX Ball 1 4184NGX ...

Page 2

Alarm signal-data Type V DC 8318 /17 ≤ 0.4 n < nG 8318 /17 H ≤ 0.4 n < nG 3312 /17 ≤ 0.4 n < nG 3314 /17 ≤ 0.4 n < nG 3318 /17 H ≤ 0.4 n ...

Page 3

Available on request: – With integrated signal latching for subsequent recognition of short-time faults. – Alarm circuit open collector or TTL. – Galvanically isolated for maximum device safety; Defects in the power circuit do not affect the alarm circuit. Alarm ...