ISE40-T1-22 SMC Corporation, ISE40-T1-22 Datasheet
ISE40-T1-22
Related parts for ISE40-T1-22
ISE40-T1-22 Summary of contents
Page 1
... Digital Pressure Switch How to Order 1 0.8 Input/Output specifications Setting range Lead wire length –100.0 to 100.0 kPa –101.3 to 101.3 kPa –1.000 to 1.000 MPa ZSE40/ISE40 Option Nil None Bracket A (ZS-24-A) A Bracket B (ZS-24-B) B Panel mount (ZS-22-A) E Panel mount (ZS-24-C) + Front protective cover F ∗ ...
Page 2
... Weight 01/T1 types approx type approx C4/C6/M5 types approx (Each including 0.6 m lead wires) Note 1) Equipped with unit switching function (Types without the unit switching function use SI units (kPa or MPa) only.) 22 Note 2) For ZSE40 (F)/ISE40- Note 3) For ZSE40 (F)/ISE40-- 70 Note 4) For ZSE40F (compound pressure) with “ ...
Page 3
... Auto Manual preset pressure setting Allows fine-tuning of the data set automatically by supply pressure auto preset. ZSE40/ISE40 Series LED (Red) Displays OUT2 output condition. When it is ON, the LED is illuminated. DOWN button Switches the mode and set value. SET button Switches to each mode and fixes the set value ...
Page 4
... Display of setting auto shift SET “SET” button. Press the “SET” button to complete the setting. ∗ Only for ZSE40(F)/ISE40--30/70(L)-M, displays the input mode “ ” and the compensation value alternately. If auto shift input is not complete, zero is displayed. ...
Page 5
... Unit Set It's only subject to ZSE40(F)/ISE40--(L). Unit selection Set the unit by either button or button. : kPa or MPa, : kgf/ bar, : psi, : inHg, : mmHg SET Press “SET” button. OUT1: Selection of the output mode Auto Preset (For adsorption confirmation) 1. Auto preset mode ...
Page 6
... ZSE40/ISE40 Series Calibration Procedures Auto Preset (In the case of confirming the supply pressure) 1. Auto preset mode Select the Auto preset mode in the initial setting mode and press the “SET” button until “ ” is displayed. ON point (C, C1) Hysteresis (3 digits) OFF ON point = C, C1 OFF point = C-3 digits, C1-3 digits (1 digit is the minimum setting unit ...
Page 7
... For splash proof use (IP65), insert an air tube into the atmospheric release port. (Refer to “Precautions” on page 16-2-24 for details.) 2-M4 x 0.7 thread depth 4 ø3.5 ∗ For splash proof use (IP65), insert an air tube into the atmospheric release port. (Refer to “Precautions” on page 16-2-24 for details.) ZSE40/ISE40 20 ZSE ISE PSE Z SE3 I ...
Page 8
... ZSE40/ISE40 Series Dimensions C4 ZSE40 ( F ) /ISE40– 32 MPa OUT1 OUT2 SET Atmospheric release port 7.8 12 One-touch fitting ø4, ø6 ∗ For splash proof use (IP65), insert an air tube into the atmospheric release port. (Refer to “Precautions” for details.) Caution 1. Immediately after supplying power, there is drift of about ±0.5% F.S. When used with very low pressure, allow the unit to warm up for about minutes ...