H335-1-71-010 Simpson, H335-1-71-010 Datasheet

no-image

H335-1-71-010

Manufacturer Part Number
H335-1-71-010
Description
Panel Meter, Digital; 120V; 4-20 DCmA Process; 3-1/2 digit, Red LED; 1 relay
Manufacturer
Simpson
Datasheet

Specifications of H335-1-71-010

Contact Form
SPST
Current, Input
4 to 20 mA mA
Height
0.56 in.
Input Type
Analog
Power Consumption
10 VA @ 9 to 36 VDC⁄120, 85 to 250 VAC
Standards
UL Listed, cUL Listed
Time, Response
200 ms (Typ.)
Voltage, Input
10
Voltage, Supply
120 VAC
Hawk 3 Advanced Digital Panel Meter & Controller
General specifications
Display:
Quantity:
Height:
Decimal Point:
Brightness:
Overrange:
Underrange:
Alarm Indicators:
Power Requirements
AC:
DC:
Accuracy @ 25ºC as percent of reading
DC Current
High (5A, 2A)
All others
DC Volts
High (600V)
All others
Resistance
All ranges
All parameters set from easy to understand
front panel access
One, two or four 5-amp relays optional
7 segment 3-1/2 or 4-1/2 digit red LED
Five user-selectable brightness levels
Activated set point indicators on display
16-point scaling linearization (H345)
Screw terminals for easy installation
1/8 DIN, shallow depth case, 3.24”
Min/Max and password lockout
12 or 24 VDC power supply output optional
4-20mA or 0-10 VDC analog retransmission optional
0.2% ± 1 count
0.05% ± 1 count
0.1% ± 1 count
0.05% ± 1 count
0.1% ± 2 counts
continued, next column
7-segment, red LED
4 or 5
0.56” (14.2 mm)
4 or 5 position, user programmable
5 levels, user programmable
Display flashes “EEEE” indicating Maximum
Value Exceeded
Display flashes “-EEEE” indicating Minimum
Value Exceeded
4 LED indicators for up to four independent
setpoints
120, 85-250 VAC @ 10VA
9-36 VDC @ 10VA
4-½ digit
:
:
0.3% ± 1 count
0.1% ± 1 count
0.2% ± 1 count
0.1% ± 1 count
0.1% ± 2 counts
3-½ digit
*AC Current
High (2A, 5A)
All others
*AC Volts
High (600V)
All others
*AC functions measured at 50 Hz, include ± 1 count for each
additional 100 Hz above 50 Hz
Environmental
Operating Temp:
Storage Temp:
Relative Humidity:
Ambient Temp:
Temperature Drift:
Warm-up Time:
Noise Rejection:
NMRR:
CMRR:
A to D Conversion
Technique:
Sample Rate:
Display Rate:
Mechanical
Depth:
Bezel:
Panel Cutout:
Case Material:
Weight:
Order Information on back side of flyer
0.2% ± 2 counts
0.1% ± 2 counts
0.1% ± 1 count
0.05% ± 1 count
0º to +50º C
-10º to +60º C
<80%
25º C
100 ppm/ºC
10 minutes
60 dB @ 50-60 Hz
70 dB @ 50-60 Hz
Successive approximation with oversampling
10 conversions per second
User programmable
1-420 updates/min (240 default)
3.24” (82.3 mm) behind panel
3.9” x 2.0” x 0.52” (99 mm x 51 mm x 13.2 mm)
3.62” x 1.77” (92 mm x 45 mm) 1/8 DIN
Flame Retardant ABS
10 oz. (283.5 g)
0.3% ± 2 counts
0.2% ± 2 counts
0.2% ± 1 count
0.1% ± 1 count