BC PRO1400 Tripp Lite, BC PRO1400 Datasheet - Page 3

UPS; 1400 VA Output; 120 VAC; 120 VAC; 8 minutes (1400 VA) Full Load

BC PRO1400

Manufacturer Part Number
BC PRO1400
Description
UPS; 1400 VA Output; 120 VAC; 120 VAC; 8 minutes (1400 VA) Full Load
Manufacturer
Tripp Lite
Type
Home/Office, Networkr
Datasheets

Specifications of BC PRO1400

Application
For Personal Computers, Network Workstations, Mid-Size & Large Business Telephone⁄Voicemail Systems, Home-Office Workstations, Small-Business Servers, Hubs, Routers and More
Approvals
UL Listed, cUL Listed
Brand/series
BC Series
Capacity
1400 VA
Color
Gray
Communication
USB
Connection, Input
NEMA 5-15P
Dimensions
32.4cmH×19.1cmW×22.9cmD
Input Type
NEMA 5-15P
Length, Cord
6 ft.
Mounting Type
Rack/Tower
Operation
Standby
Output Type
(6) NEMA 5-15R
Power, Rating
940 W
Receptacle Style
6 NEMA 5-15R
Run Time
8 minutes (1400 VA) Full Load
Time, Backup
8 min.
Voltage, Input
120 VAC
Voltage, Output
120 VAC
Voltage, Supply
940/1400 W/VA
Weight
16.5 kg
Power Rating
1400 VA
Output Voltage Rating
120 V
Number Of Outlets
6
Interface Port
USB
Runtime (full Load)
8 min
Runtime (half Load)
24 min
Topology
Standby
Tower / Rackmount
Tower
Lead Free Status / Rohs Status
RoHS Compliant part
Alarms
Switches
SURGE / NOISE SUPPRESSION
AC surge suppression
AC suppression
response time
Dataline suppression
EMI / RFI AC noise
suppression
PHYSICAL
Shipping weight (lbs)
Shipping weight (kg)
Unit weight (lbs)
Unit weight (kg)
Unit Dimensions
(HWD/in)
Unit Dimensions
(HWD/cm)
Material of
construction
Form factors
supported
Cooling method
Battery Access
ENVIRONMENTAL
Operating
Temperature
Storage Temperature
Relative Humidity
COMMUNICATIONS
Network monitoring
port
WatchDog
compatibility
LINE / BATTERY TRANSFER
Transfer time from
line power to battery
mode
Low voltage transfer
to battery power
High voltage transfer
to battery power
SPECIAL FEATURES
Cold Start
Appearance
CERTIFICATIONS
Audible alarm with 15 second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front
panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain.
Includes 2 front panel switches—one main on/off power switch and one dual function "alarm cancel" / "self test" button
480 joules
Instantaneous
-
Yes
40
18.2
36.4
16.5
12.75 x 7.5 x 9
32.4 x 19.1 x 22.9
PVC
Tower
Convection
Battery access door allows user replacement of UPS batteries
+32 to +104 degrees Fahrenheit
+5 to +122 degrees Fahrenheit
0 to 95%, non-condensing
USB
Compatible with Tripp Lite's Watchdog system service to restore operation to locked equipment through soft reboot of
application / OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications
2-4 milliseconds
Switches to battery power as line voltage decreases to 99 volts or less. Resets back to line power mode as line
voltage increases to 104V or higher.
Yes
Yes, inverter can be "cold started" to enable temporary AC output during a power failure
Attractive gray tower UPS

Related parts for BC PRO1400