U1251A Agilent Technologies Test Equipment, U1251A Datasheet - Page 6

no-image

U1251A

Manufacturer Part Number
U1251A
Description
Handheld Digital Multimeter, 50, 000 Count Dual Display, 4.5 Digit Resolution
Manufacturer
Agilent Technologies Test Equipment
Datasheet

Specifications of U1251A

Battery Life
72 hours typical
Capacitance
10 nF to 100 mF
Current, Range
500 μA to 10 A
Dimensions
203.5 × 94.4 × 59.0 mm
Display Type
5 Digit LCD dual display
Frequency Range
99.999 Hz to 999.99 kHz
Impedance, Input
10 MOhm
Power Consumption
105/420 (with backlight) mVA
Resistance, Range
500 Ω to 500 MΩ
Voltage, Range, Ac
50 mV to 1000 V
Voltage, Range, Dc
50 mV to 1000 V
Weight
504 g (with battery)
U1252A/U1253A AC+DC SPECIFICATIONS
CAPACITANCE SPECIFICATIONS
FREQUENCY SPECIFICATIONS
[1] The additional error to be added as frequency >20 kHz and signal input <10% of range: 3 counts of LSD per kHz.
[2] The input signal is lower than 20,000,000 V-Hz (the product of voltage and frequency).
[3] Input current >35 µArms.
[4] Current can be measured from 2.5 A up to 10 A continuously. An additional 0.5% needs to be added to the specifi ed accuracy if the signal measured is in the range
[5] Input current < 3 Arms.
[6] For non-square wave signals, add 5 counts.
TRUE RMS AC
AC CURRENT
FUNCTION
FUNCTION
of 10 A ~ 20 A for 30 seconds maximum. After measuring a current of >10 A, leave the meter to cool down for twice the measuring time used before application of
low current measurement.
VOLTAGE
10.000 mF
100.00 mF
10.000 nF
100.00 nF
1000.0 nF
10.000 µF
100.00 µF
1000.0 µF
RANGE
9.9999 kHz
99.999 kHz
999.99 kHz
99.999 Hz
999.99 Hz
RANGE
500.00 µA
50.000 mV
500.00 mV
1000.0 mV
50.000 mA
440.00 mA
10.000 A
1000.00 V
5000.0 µA
5.0000 V
50.000 V
500.00 V
5.0000 A
RANGE
RANGE
[4]
[3]
RESOLUTION
[2]
RESOLUTION
RESOLUTION
0.001 mA
0.001 mV
0.0001 V
0.0001 A
0.01 mV
0.01 mA
0.001 mF
0.01 µA
0.001 V
0.001 A
0.001 nF
0.001 µF
0.1 mV
0.01 mF
0.01 V
0.1 µA
0.01 nF
0.01 µF
0.1 V
0.1 nF
0.1 µF
RESOLUTION
0.0001 kHz
0.001 kHz
0.001 Hz
0.01 kHz
0.01 Hz
30 Hz ~ 45 Hz
1.5+80
1.5+65
30 Hz ~ 45 Hz
1.8+30
1.1+25
1.2+25
ACCURACY
[5]
ACCURACY ± (% of reading + No. of Least Signifi cant Digit)
ACCURACY ± (% of reading + No. of Least Signifi cant Digit)
3% + 10
1% + 8
1% + 5
45 Hz ~ 1 kHz
6
0.4+30
0.4+60
0.4+45
0.02%+3, <600 kHz
U1251A/2A
0.02%+3
[6]
45 Hz ~ 1 kHz
1 kHz ~ 10 kHz
ACCURACY
MEASURING RATE AT
FREQUENCY
FREQUENCY
0.8+25
0.9+25
0.9+30
0.9+25
0.7+60
0.4+30
0.4+45
0.01 times/sec
0.1 times/sec.
FULL SCALE
4 times/sec.
1 time/sec.
0.02%+3, <600 kHz
0.02%+3
U1253A
10 kHz ~ 20 kHz
1.5+45
[6]
0.8+60
0.8+45
1.5+45
[2]
1 kHz ~ 20 kHz
<3 A/5 kHz
MAX. DISPLAY
11000 counts
3.3+70,
0.8+25
0.9+25
20 kHz~100 kHz
MIN. INPUT
FREQUENCY
3.5+125
1 Hz
3.5+220
3.5+125
N/A
[2]
[1]