LY2-0-DC100/110 Omron Automation, LY2-0-DC100/110 Datasheet
LY2-0-DC100/110
Specifications of LY2-0-DC100/110
Available stocks
Related parts for LY2-0-DC100/110
LY2-0-DC100/110 Summary of contents
Page 1
... LY2Z LY2ZF LY2ZS — — — — — — — — — LY2Z-0 — — — — — — — — — — — LY2ZN — — — — — — — — ...
Page 2
... LY2Zl2 — — — — — — — — LY2Zl2N — — — — — Mounting track RC circuit PFP-100N/PFP-50N & PFP-M or PFP-100N2 PFP-S (Option spacer) Socket Mounting Plate PYP-1 – – PYP-18 PTP-1-3 – ...
Page 3
Specifications ■ Contact Data Load SPDT Resistive load (p. Rated load 110 VAC 110 VAC VDC VDC Contact material Ag-Alloy Carry current 15 A ...
Page 4
Type – AC Rated Rated current (mA) voltage (V) resistance 310 270 6.70 12 159 134 100 410 100/110 15.90/18.30 13.60/15.60 2,300 120 17.30 14.8 2,450 200/220 ...
Page 5
... DC: 100 million operations min. (at operating frequency of 18,000 operations/hour) See “Characteristic Data” SPDT, DPDT: Approx (1.41 oz), 3PDT: Approx (1.76 oz) 4PDT: Approx (2.47 oz) LY3, LY4 Rated operating voltage (V) LY3, LY4 Switching current (A) General Purpose Relay LY2Z Rated operating voltage (V) LY2Z Switching current ( ...
Page 6
... LY1-0, LY2-0, LY3-0, LY4-0 Note: The above drawing shows LY2-0. With LY1-0, dimension “*” should read as eight 6.35 (.25). LY1F, LY2F Note: The above drawing shows LY1F. With LY2F, dimension “*” should read as eight 3.05 mm (0.12 in) dia. holes. 6 General Purpose Relay ...
Page 7
... LY4F LY1S, LY2S Note: The above drawing shows LY2S-US. With LY1S-US, dimension “*” should read as eight 2.03 mm (0.08 in) dia. holes. LY3S LY4S Mounting holes Round hole Rectangular hole Round hole Rectangular hole Round hole Rectangular hole General Purpose Relay LY 7 ...
Page 8
Accessories Unit: mm (inch) Track mounted sockets (UL File No. E87929) (CSA Report No. LR31928) PTF08A Terminal arrangement/ (see note 3) mounting holes (Top view) Track mounting sockets (UL File No. E87929) (CSA Report No. LR31928) PTF14A Terminal arrangement/ ...
Page 9
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928) PT14 Terminal arrangement (Bottom view) Note: Values in brackets for LY❏CR. Back connecting socket (UL File No. E87929) (CSA Report No. LR31928) PT08QN Panel cut-out and terminal arrangement are ...
Page 10
Unit: mm (inch) Relay hold-down clips PYC-A1 For PTF❏A socket Relay hold-down clips PYC-P2 For push-to-test button type with PT❏ socket Mounting track/end plate/spacer PFP-100N/PFP-50N mounting track 10 General Purpose Relay PYC-S For relay mounting plates (Applicable to Type PYP-1 ...
Page 11
PFP-100N2 mounting track *This dimension is 14.99 mm (0.59 in) on both ends in the case of PFP-100N, but on one end in the case of PFP-50N. **L = Length PFP-50N L = 497.84 mm (19.60 in) PFP-100N L = ...
Page 12
... Note: 1. Pay special attention to the polarities when using the DC type. 2. The release time is somewhat longer, but satisfies the standard specifications of 25 ms. 3. The reverse-breakdown voltage of the diode is 1,000 VDC. 4. Available on DC versions only. 12 General Purpose Relay AC coil rating type With Diode LY2N-D2 6, 12, 24, 48 VDC LY LY2N-D2 100/110 VDC ...
Page 13
... Push-to-test Button Specifications and dimensions same as the Standard Type with the following exceptions. LY❏12 Note: Type LY112 has the same dimensions and appearances as Type LY212 shown except that dimensions “*” is 2.03 mm (0.08 in) dia. holes. LY312 With RC circuit Terminal arrangement/Internal connections (Bottom view) ...
Page 14
Approvals UL Recognized Type (File No. E41643) Type Contact form LY❏ SPDT LY❏ DPDT LY❏ 3PDT 4PDT CSA Certified Type (File No. LR31928) Type Contact form LY❏ SPDT LY❏ DPDT LY❏ 3PDT 4PDT VDE Approved Type (File No. 9903 ...
Page 15
Omron Electronic Components, LLC Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer ...
Page 16
Certain Precautions on Specifications and Use 1. Suitability for Use. Seller shall not be responsible for conformity with any stan- dards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. ...