E2E2-X10MY1-US Omron Automation, E2E2-X10MY1-US Datasheet - Page 2

no-image

E2E2-X10MY1-US

Manufacturer Part Number
E2E2-X10MY1-US
Description
Sensor, Proximity; Inductive Sensing Mode; M18; 10 mm; 24 to 240 VAC; 25 Hz
Manufacturer
Omron Automation
Type
Inductiver
Datasheet

Specifications of E2E2-X10MY1-US

Body Style
Cylindrical
Current, Leakage
1.7 mA (Max.)
Current, Switching
300 mA
Frequency, Operating
50⁄60 Hz
Frequency, Switching
25 Hz
Function
Proximity
Indicator
Red LED (Operation Indicator)
Ip Rating
IP67
Material, Housing
Thick Nickel Plated Brass
Mounting Type
M18 Threaded
Output
NO
Primary Type
Proximity
Range, Measurement
10 mm
Standards
UL Recognized, CSA Certified, CE Marked
Technology
Inductive
Temperature Range
-40 to +85 °C
Termination
Pre-Wired
Voltage, Supply
24 VDC
Voltage, Switching
3 V
Supply Voltage Range
10-55 VDC or 20-264 VAC, 50/60 Hz (Model Dependant)
Load Rating
200 mA (DC) or 5-200 mA/5-300 mA (AC) (Model Dependant)
Approvals
CE, UL, CSA (Model Dependant)
Lead Free Status / Rohs Status
RoHS Compliant part
Accessories (Order Separately)
Mounting Brackets
Protective Covers
Sputter Protective Covers
Ratings and Specifications
E2E2-X@D@ DC 2-Wire Models
*1. Use the E2E2 within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
Item
Sensing distance
Set distance *1
Differential travel
Sensing object
Standard sensing object
Response frequency *2
Power supply voltage
(operating voltage range)
Leakage current
Control
output
Indicators
Operation mode
(with sensing object ap-
proaching)
Protection circuits
Ambient temperature
Ambient humidity
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
(destruction)
Shock resistance
(destruction)
Degree of protection
Connection method
Weight (packed state)
Materi-
als
Accessories
a set distance of half the sensing distance.
Switching
capacity
Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m)
Case
Sensing surface PBT
Clamping nuts
Toothed washer Zinc-plated iron
Shielding
Model
Size
3 mm±10%
0 to 2.4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on
page 5.)
Iron,
12 × 12 × 1 mm
1 kHz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
0.8 mA max.
3 to 100 mA
D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
D1 Models: NO
D2 Models: NC
Surge absorber, Load short-circuit protection
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
1,000 m/s
IEC IP67, in-house standard for oil resistance
Pre-wired Models (Standard cable length: 2 m)
Approx. 65 g
Brass
Nickel-plated brass
Instruction sheet
E2E2-X3D@
Shielded
2
10 times each in X, Y, and Z directions
M12
Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
8 mm±10%
0 to 6.4 mm
Iron,
30 × 30 × 1 mm
800 Hz
E2E2-X8MD@
Unshielded
7 mm±10%
0 to 5.6 mm
Iron,
18 × 18 × 1 mm
500 Hz
Approx. 150 g
E2E2-X7D@
Shielded
M18
14 mm±10%
0 to 11.2 mm
Iron,
30 × 30 × 1 mm
400 Hz
E2E2-X14MD@
Unshielded
10 mm±10%
0 to 8 mm
Iron,
30 × 30 × 1 mm
Approx. 210 g
E2E2-X10D@
Shielded
M30
E2E2-X20MD@
20 mm±10%
0 to 16 mm
Iron,
54 × 54 × 1 mm
100 Hz
Unshielded
E2E2
2

Related parts for E2E2-X10MY1-US