3120-F321-P7T1-W01K-15 E-T-A Circuit Protection and Control, 3120-F321-P7T1-W01K-15 Datasheet - Page 9

no-image

3120-F321-P7T1-W01K-15

Manufacturer Part Number
3120-F321-P7T1-W01K-15
Description
Circuit Breaker; DPST; 15 A; 4 to 7 V; 10000 Operations; gt 100 Megohms; Blade
Manufacturer
E-T-A Circuit Protection and Control
Datasheet

Specifications of 3120-F321-P7T1-W01K-15

Contact Form
DPST
Dielectric Rating
3000 V (Operating Area), 1500 V (Between Poles)
Dimensions
2.13 in. L x 0.984 in. W x 1.30 in. H
Electrical Life
10000 Operations
Resistance, Insulation
> 100 Megohms
Standards
EN and IEC Approved
Temperature, Operating, Maximum
+60 °C
Temperature, Operating, Minimum
-30 °C
Voltage, Rating
4 to 7 V
Lead Free Status / Rohs Status
RoHS Compliant part
Switch/thermal trip free circuit breaker (S-type TO CBE to EN 60934) with
standard isolator style two button operation. Single button press-to-reset
version also available. Both types can be supplied in single pole
configuration only, in double pole with single pole protection, and in double
pole with protection on both poles. Designed for snap-in panel mounting.
There is a choice of push button colour combinations and illumination is
optional.
Any one of the following additional function modules can be supplied
factory fitted to the rear of the switch/circuit breaker:
G
G
G
G
G
Approved to CBE standard EN 60934 (IEC 60934).
Motors, transformers, solenoids, extra low voltage wiring systems, office
machines, electro-medical equipment, power supplies, communications
systems, industrial controls.
Current
rating (A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
operating voltage
* single pole version only
Authority
VDE, (EN 60934)
BV
UL, CSA
CCC
05/06
Description
Typical applications
Standard current ratings and typical internal resistance values
Illumination voltage/power consumption
Approvals
Under voltage release coil (for double pole versions only).
Magnetic trip coil for short circuit protection.
Magnetic trip coil for remote relay trip.
Auxiliary contacts for status signalling.
Mechanical slide interlock.
6 V
12 V
24 V
48 V
115 V
230 V
415 V
(280405)
Internal resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
Thermal Overcurrent Circuit Breaker 3120-F...
Voltage ratings
AC 240 V, DC 28 V
DC 50 V
DC 50 V
AC 250 V, DC 28 V
AC 250 V, DC 50 V
AC 250 V, DC 50 V
filament/neon
60 mA
20 mA
20 mA
20 mA
< 1.5 mA
< 1.5 mA
< 1 mA
power consumption
Current
rating (A)
3.5
4
4.5
5
6
7
8
10
12
14
16
18
20
Internal resistance
per pole (Ω)
0.0565
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Current ratings
0.1...20 A
0.1...20 A 2 pole
0.1...10 A 1 pole
0.1...20 A
0.1...20 A
0.1...20 A
LED
9 mA
9 mA
9 mA
1.5 mA
< 1 mA*
< 1 mA*
not available
www.e-t-a.com
For further details please see chapter: Technical Information
Voltage rating
Current ratings
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A
Dielectric strength
(IEC 60664 and 60664A)
Insulation resistance
Interrupting capacity I
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Technical data
AC 240 V:
DC 50 V:
DC 28 V:
AC 415 V:
AC 240 V:
DC 50 V:
operating area
between poles (2 pole)
0.1...20 A 30,000 operations at 1 x I
0.1...4 A
4.5...16 A 30,000 operations at 1 x I
4.5...20 A 30,000 operations at 1 x I
0.1...16 A 10,000 operations at 1 x I
0.1...16 A 50,000 operations at 1 x I
17...20 A
0.1...16 A 50,000 operations at 1 x I
17...20 A
cn
AC 240 V; DC 50 V
(AC 415 V to special order)
(UL: AC 250 V; DC 50 V)
0.1...20 A
(up to 30 A to special order, single pole only)
1 pole
30,000 operations at 1 x I
2 pole
30,000 operations at 1 x I
10,000 operations at 1 x I
-30...+60 °C (-22...+140 °F)
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V
AC 1,500 V
>100 MΩ (DC 500 V)
0.1...2 A 10 x I
2.5...20 A 250 A 2 pole, or 150 A 1 pole
I
0.1...2 A
2.5...3 A
3.5...8 A
9...16 A
18...20 A
0.1...20 A
operating area IP40
terminal area IP00
8 g (57-500 Hz), ±0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-3, test Ca
approx. 33 g (double pole)
approx. 27 g (single pole)
N
3120-F...
U
AC 250 V
AC 250 V
AC 250 V
AC 250 V
AC 250 V
DC 50 V
N
N
pollution
degree
2
N
N
N
N
N
N
N
N
N
, inductive
, inductive
, resistive
, inductive
, inductive
, inductive
, inductive
, inductive
, inductive
2 pole
200 A
1,000 A
2,000 A
3,500 A
5,000 A
1,000 A
79
1

Related parts for 3120-F321-P7T1-W01K-15