GLM50D SL Power ( Ault / Condor ), GLM50D Datasheet - Page 2

no-image

GLM50D

Manufacturer Part Number
GLM50D
Description
Power Supply, Switching; 50 W; 5.1 V; 24 V; -12 V; 0 to degC; 5 Oz.
Manufacturer
SL Power ( Ault / Condor )
Type
Medicalr
Datasheet

Specifications of GLM50D

Brand/series
GLM50 Series
Configuration
Open-Frame
Mounting Type
Panel
Number Of Outputs
3
Operation
Switching
Output
-12 VDC @ 0.2 A, +5.05 VDC @ 4 A, +24 VDC @ 1.5 A
Power, Output
50 W
Power, Rating
50 W
Primary Type
AC-DC
Standards
UL Listed, CSA Certified, IEC and CE Marked
Temperature Coefficient
0.03 %⁄°C (Typ.)
Temperature, Operating
0 to +50 °C
Voltage, Input
90 to 264 VAC
Voltage, Output
-12, +5.05, +24 VDC
Voltage, Output 1
5.1 V
Voltage, Output 2
24 V
Voltage, Output 3
-12 V
Weight
5 Oz.
Notes:
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. To maintain specified regulation on multi-output models, output #1 load power must be at least 1/5th of, and not greater than 5 times output #2 load power.
C. Add “G” suffix to model number for RoHS compliant model.
Commercial
Model
GLC50A
GLC50B
GLC50D
GLC50G
GLC50-3.3
GLC50-5
GLC50-12
GLC50-15
GLC50-24
GLC50-28
GLC50-48
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
GLC50 MECHANICAL SPECIFICATIONS
Medical
Model
GLM50A
GLM50B
GLM50 D
GLM50G
GLM50-3.3
GLM50-5
GLM50-12
GLM50-15
GLM50-24
GLM50-28
GLM50-48
Output No.
OPERATING
0 TO 50°C
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
pk
1
2
3
1
2
3
1
2
3
1
2
3
1
1
1
1
1
1
1
rms’
0.003 g
2
/Hz
+5.05 V
+5.05 V
+5.05 V
Output
+3.3 V
+12 V
+15 V
+24 V
+12 V
-12 V
-15 V
-12 V
-12 V
3.3 V
5.1 V
12 V
15 V
24 V
28 V
48 V
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
rms’
pk
0.026 g
2
/Hz
Current
2.5 A
0.2 A
2.5 A
0.2 A
1.5 A
0.2 A
2.5 A
0.2 A
4.2 A
3.3 A
2.1 A
1.8 A
1.1 A
4 A
4 A
4 A
4 A
8 A
8 A
A. Units should be allowed to warm up/operate under non-condensing condi-
tions before application of power. derate output current and total output
power by 2.5% per °C above 50°C.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal
axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
Minimum
Load (B)
0.8 A
0.8 A
0.8 A
0.8 A
0.16
0.09
0.05
0.2
0.4
0.2
0.1
OVP Setpoint
18.5 ± 1.5 V
34.5 ± 2.8 V
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
4.2 ± 0.6 V
4.2 ± 0.6 V
6.2 ± 0.6 V
14 ± 1.1 V
28 ± 2.5 V
54 ± 3.0 V
Noise P-P
120 mV
120 mV
150 mV
150 mV
240 mV
120 mV
120 mV
120 mV
120 mV
150 mV
240 mV
280 mV
480 mV
50 mV
50 mV
50 mV
33 mV
66 mV
75 mV
Regulation (A)
+10%,-5%
+10%,-5%
+10%,-5%
+10%-5%
Total
2%
3%
2%
3%
2%
3%
2%
3%
2%
2%
2%
2%
2%
2%
2%

Related parts for GLM50D