G7J-4A-BW-1-AC200/240 Omron Automation, G7J-4A-BW-1-AC200/240 Datasheet - Page 3

no-image

G7J-4A-BW-1-AC200/240

Manufacturer Part Number
G7J-4A-BW-1-AC200/240
Description
RELAY; E-MECH; GEN PURP; 4PST-NO; CUR-RTG 25A; CTRL-V 200/240AC; VOL-RTG 220/30AC/DC
Manufacturer
Omron Automation
Datasheet

Specifications of G7J-4A-BW-1-AC200/240

Contact Form
4PST-NO
Current, Rating
25 A
Dielectric Rating
4000 VAC
Dimensions
2.028 in. (Max.) L x 1.358 in. (Max.) W x 2.520 in. (Max.) H
Function
General Purpose
Mounting Type
Bracket
Power, Rating
5500⁄750 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA, CE
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-25 °C
Termination
Screw
Voltage, Control
220 VAC
Voltage, Rating
250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
■ Coil Internal Circuit
AC operating coil
The G7J incorporates a bridge rectifier circuit in the AC coil versions
that prevents contact chatter or dropout during a voltage drop. This
circuit allows the relays to withstand, with no vibration or shock, volt-
age drops to the coil of up to 50% of the rated coil voltage for one
second maximum.
■ Characteristics
Note: Data shown are of initial value.
Contact resistance
Operating time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Impulse withstand voltage
Vibration
Shock
Service life
Ambient temperature
Humidity
Weight
A2
Mechanical
Electrical
Mechanical durability
Malfunction durability NO: 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
Mechanical durability
Malfunction durability NO: 100 m/s
Mechanical
Electrical
Operating
Operating
PCB terminal
Screw terminal
50 mΩ max.
50 ms max.
50 ms max.
1,800 operations/hour max.
1,800 operations/hour max.
1,000 MΩ minimum at 500 VDC
4,000 VAC, 50/60 Hz for 1 minute between coil and contacts
4,000 VAC, 50/60 Hz for 1 minute between contacts of different polarity
2,000 VAC, 50/60 Hz for 1 minute between contacts of the same polarity
10,000 V between coil and contact with 1.2 x 50 µs impulse wave
10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
NC: 10 to 26 Hz, 1.50 mm (0.06 in) double amplitude
1000 m/s
NC: 20 m/s
1 million operations minimum at 1,800 operations/hour
100,000 operations minimum at 1,800 operations/hour at rated load
-25° to 60°C (-13° to 140°F) with no icing
35% to 85% RH
Approx. 140 g (4.90 oz.)
Approx. 165 g (5.80 oz.)
A1
2
(Approx. 100 G)
2
2
(Approx. 2 G)
(Approx. 10 G)
DC operating coil
As a rule, either a DC battery or a DC power supply with a maximum
of 5% ripple must be used for the operating voltage for DC relays.
Before using a rectified AC supply, confirm that the ripple is not
greater than 5%. Ripple greater than this can lead to variations in
the operating and reset voltages. As excessive ripple can generate
pulses, the insertion of a smoothing capacitor is recommended as
shown below.
When driving the coil with a transistor, check the leakage current and
connect a bleeder resistor if necessary.
E max.:Maximum ripple
E min.:Minimum ripple
E mean:Mean DC voltage value
A2
% of ripple = E max.
General Purpose Relay
E min. E max.
E mean
E mean
E min. x 100
Smoothing
capacitor
G7J
Ripple
DC fraction
A1
Relay
3