VMP012D Macromatic, VMP012D Datasheet - Page 2

no-image

VMP012D

Manufacturer Part Number
VMP012D
Description
Relay; E-Mech; Voltage Monitor; DPDT; Cur-Rtg 10A; Ctrl-V 12DC; Vol-Rtg 240/30AC/DC
Manufacturer
Macromatic
Datasheet

Specifications of VMP012D

Brand/series
VMP Series
Contact Form
DPDT
Current, Rating
10 A
Display Type
LED
Function
Voltage Monitor
Mounting Type
Socket
Number Of Pins
8
Relay Type
Electro Mechanical
Release Time
500 ms
Standards
cULus, UL, CE
Temperature, Operating
-28 to +55 °C
Termination
Plug-In
Voltage, Control
12 VDC
Voltage, Rating
240⁄30 VAC⁄VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Operating Modes
These relays can be used as either overvoltage or undervoltage relays, depending on the output contact used:
Overvoltage Relay
Provides protection to equipment that cannot handle excess
voltages. Uses a normally closed contact (N.C.). As long as the
monitored voltage remains below the maximum voltage the
equipment can withstand (Pick-Up Setting), the relay remains de-
energized and the N.C. contact remains closed, keeping the load
energized. If the operating voltage increases beyond the maxi-
mum rating of the equipment, the relay energizes and the N.C.
contact opens, turning off the load. When the voltage falls below
the Drop-Out Setting (hysteresis), the relay de-energizes and the
N.C. contact re-closes, turning on the load.
Application Data
Voltage Tolerance:
+25%/-50% of nominal voltage; AC voltages are 50-60Hz;
No separate supply (input) voltage is required.
Load (Burden): Less than 3VA
Voltage Settings:
Pick-up:
Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series)
Temperature:
-28
Output Contacts:
10A @ 240V AC/30V DC, 1/2HP @ 120/240V AC (N.O.),
1/3HP @ 120/240V AC (N.C.)
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Dimensions
Revised: 11/07
o
to 55
o
2.4 (60)
C (-20
Adjustable from 85-115% of nominal voltage
Adjustable from 75-95% of pick-up setting (VMKP &
VAKP Series)
o
to 131
o
F)
1.7 (43)
VOLTAGE MONITOR RELAYS
Inches (Millimeters)
All Dimensions in
VM & VA Series Over/Undervoltage
Response Times:
Operate: 500ms
Release: Fixed 500 ms (VMP & VMKP Series)
Indicator LED: Red Steady when Relay is energized; Green
when Relay is Off.
Transient Protection:
10,000 volts for 20 microseconds
Reset: Automatic. Contact Macromatic for information on
how to order a unit with Manual Reset.
Approvals:
2.9 (74)
Undervoltage Relay
Provides protection to equipment that is required to
operate above a certain minimum voltage. Uses a
normally open contact (N.O.). As long as the monitored
voltage is above the minimum value required (Pick-Up
Setting), the relay will energize and the N.O. contact
closes, turning on the load. If the voltage drops below the
Drop-out Setting (the minimum voltage required minus
the hysteresis), the relay will de-energize and the N.O.
contact will re-open, turning off the load.
File #E109466
3.5 (89)
Adjustable 0.5 - 10 Seconds (VAP & VAKP Series)
Application Data & Dimensions
Macromatic socket
with appropriate
File #E109466
VMKP & VAKP
Only
27

Related parts for VMP012D