UC2000-30GM-IUR2-V15 Pepperl + Fuchs, UC2000-30GM-IUR2-V15 Datasheet - Page 3

no-image

UC2000-30GM-IUR2-V15

Manufacturer Part Number
UC2000-30GM-IUR2-V15
Description
Sensor, Proximity; 120m to 2 m; 10 to 30 VDC; 900 mW; 4 to 20 mA; 0.1%; 180 kHz
Manufacturer
Pepperl + Fuchs
Type
Ultrasonicr
Datasheet

Specifications of UC2000-30GM-IUR2-V15

Body Style
Cylindrical
Current, Switching
4 mA
Frequency, Transducer
180
Function
Proximity
Ip Rating
IP65
Material, Housing
303 Stainless Steel
Output
Voltage/Current
Power Consumption
900 mW
Primary Type
Proximity
Range, Measurement
2 m
Repeatability
0.1%
Standards
UL Listed, CSA Certified, CE Approved
Technology
Ultrasonic
Termination
Quick Disconnect
Transducer Type
Epoxy Resin⁄Silica Composite
Voltage, Supply
30 VDC
Input Voltage
10-30 VDC (15-30 VDC for Analog Voltage Output)
Operating Temperature
–14°F to +158°F
Sensing Face
Epoxy Resin/Silica Composite
Housing Material
Nickel-Plated Brass (UB), Stainless Steel (UC)
Sensor Protection
Short-Circuit, Overload, Reverse Polarity
Sealing
IP 65
Standard Target
100 mm × 100 mm Flat Plate
Connection Type
V15
Lead Free Status / Rohs Status
RoHS Compliant part
310
Modes of Operation
E4
E5
V15 Type
Wiring Diagrams
Dual Switch Point Output
Single Switch Point Output
NPN Normally open
or Normally closed
PNP Normally open
or Normally closed
Ultrasonic Sensors
Note: Wiring diagrams show
Window Mode
Sensor
Sensor
Quick Disconnect
Window Mode
1
4
5
3
2
1
2
5
4
3
quick disconnect pin numbers.
Sync. Input
Programming Input
Programming Input
Sync. Input
Boundary (B1)
Point 1 (B1)
Window
4
1
4
1
Switch
Male Receptacle End View
5
5
Black
Blue
3
Blue
2
3
2
Brown
Brown
Black
White
Gray
Gray
White
Target
Target
Sync. Input
Programming Input
Load
Sync. Input
Programming Input
Load
Boundary (B2)
Point 2 (B2)
Window
Switch
E6R2
E7R2
IUR2
PNP Normally open
or Normally closed
NPN Normally open
or Normally closed
Setpoint Mode
Setpoint Mode
1
5
2
4
3
1
2
4
5
3
Sensor
1
5
2
4
3
Sensor
Output 1
Output 2
Current
Analog
Sync. Input
Sync Input
Sync Input
Analog
Voltage
Output 2
Output 1
Switch Point and Analog Outputs
Male Receptacle End View
4
1
Black
Male Receptacle End View
5
4
1
4
1
Black
Point 1 (B1)
5
5
Black
Boundary
Brown
Blue
Switch
3
Window
2
Brown
Blue
Blue
3
3
2
2
Gray
White
Brown
White
Gray
Gray
White
Sync Input
Load
Sync.
Input
Target
Target
Programming
Output 1
Output 2
Input
Current
Analog
Voltage
Analog
Output
Output
2
1
Point 2 (B2)
Switch
A1 Active
A2 Active

Related parts for UC2000-30GM-IUR2-V15