Frequency (53131A, 53132A, 53181A)
Channel 1 and 2 (53131A, 53132A)
Channel 1 (53181A)
Range
Channel 3 (53131A, 53132A)
Channel 2 (53181A)
Option 015
(53181A only)
Option 030
Option 050
Option 124
(Period 2 or 3 selectable via GPIB only)
Period (53131A, 53132A, 53181A)
Channel 1 and 2 (53131A, 53132A)
Channel 1 (53181A)
Range
Channel 3 (53131A, 53132A)
Channel 2 (53181A)
Option 015
(53181A only)
Option 030
Option 050
Option 124
Frequency Ratio (53131A, 53132A, 53181A)
Measurement is specified over the full signal
range of each input.
Results Range
“Auto” Gate Time 100 ms
Time Interval (53131A, 53132A)
Measurement is specified over the full signal
ranges
Results Range -1 ns to 10
LSD
Measurement Specifications
6
of Channels 1 and 2.
0.1 Hz to 225 MHz
100 MHz to 1.5 GHz
100 MHz to 3 GHz
200 MHz to 5 GHz
200 MHz to 12.4 GHz
4.44 ns to 10 s
0.66 ns to 10 ns
0.33 ns to 10 ns
0.2 ns to 5 ns
80 ps to 5 ns
500 ps (53131A)/150 ps (53132A)
10
-10
to 10
5
11
s
Phase (53131A, 53132A)
Measurement is specified over the
full signal range of Channels 1 and 2.
Results Range -180° to +360°
Duty Cycle (53131A, 53132A)
Measurement is specified over the full
signal range of Channel 1. However, both the
positive and negative pulse widths must be
greater than 4 ns.
Results Range 0 to 1 (e.g. 50% duty cycle
Rise/Fall Time (53131A, 53132A)
Measurement is specified over the full signal
ranges of Channel 1. The interval between the
end of one edge and start of a similar edge
must be greater than 4 ns.
Edge Selection Positive or Negative
Trigger
Results Range 5 ns to 10
LSD
Pulse Width (53131A, 53132A)
Measurement is specified over the full signal
range of Channel 1. The width of the opposing
pulse must be greater than 4 ns.
Pulse Selection Positive or Negative
Trigger
Results Range 5 ns to 10
LSD
Totalize (53131A, 53132A)
Measurement is specified over the
full signal range of Channel 1.
Results Range 0 to 10
Resolution
would be displayed as .5)
Default setting is Auto Trigger
at 10% and 90%
500 ps (53131A)/150 ps (53132A)
Default setting is Auto Trigger
at 50%
500 ps (53131A)/150 ps (53132A)
± 1 count
15
6
5
5
s
s
Peak Volts (53131A, 53132A, 53181A)
Measurement is specified on Channels 1 and 2
for dc signals; or for ac signals of frequencies
between 100 Hz and 30 MHz with peak-to-peak
amplitude greater than 100 mV.
Results Range -5.1 V to +5.1 V
Resolution
Peak Volts Systematic Uncertainty
for ac signals: 25 mV + 10% of V
for dc signals: 25 mV + 2% of V
Use of the input attenuator multiplies all
voltage specifications (input range, results
range, resolution and systematic uncertainty)
by a nominal factor of 10.
Gate Time
Auto Mode, or 1 ms to 1000 s
Measurement Throughput
GPIB ASCII
Measurement Arming
Start
Measurement
Stop
Measurement
Time Interval
Delayed
Arming
Arming Modes
(Note that not all arming modes are available for
every measurement function.)
5. Available for all measurements except Peak Volts.
6. See Specifications for Pulse Width and Rise/Fall
External Arm is referred to as External Gate for some
measurements.
Time measurements for additional restrictions on
signal timing characteristics
10 mV
200 measurements/s (maximum)
Free Run, Manual, or External
Continuous, Single, External,
or Timed
100 µs to 10 s (53131A)
100 ns to 10 s (53132A)