9902090 CW BEI Duncan, 9902090 CW Datasheet - Page 2

no-image

9902090 CW

Manufacturer Part Number
9902090 CW
Description
Hall Effect Sensor, 5V input, 3% at optimum temp
Manufacturer
BEI Duncan
Type
Rotaryr
Datasheet

Specifications of 9902090 CW

Brand/series
9900 Series
Function
Position
Ip Rating
IP67
Technology
Hall Effect
Termination
6-Pin Connector
Voltage, Supply
5 VDC
Voltage, Switching
4.5 V
Mechanical Travel
–90° to +90°
Frequency Response
1 KHz Min.
Weight
40 Grams Max.
Mechanical Input Range
–45° to 45°
Input Voltage
5.0 V ±0.25 VDC
Input Current
10 mA Maximum Per Output; 20 mA Max. Total
Sensor 1 Output
0.50 V to 4.50 V
Sensor 2 Output
0.25 V to 2.25 V
Electromagnetic Compatibility
100 V/Meter, 14 KHz to 1 GHz
Vibration
5 GHz Peak 60-200 Hz
Shock
50 GHz, Half-Sine Pulse 5 ms Duration
Operation Temperature
–40°C to +85°C
Mechanical Specifications
Mechanical Travel
Frequency Response
Rotational Torque
Weight
Electrical Specifications
Mechanical Input Range
Input Voltage
Input Current
Sensor 1 Output
Sensor 2 Output
Accuracy
Resolution
Environmental Specifications
Electromagnetic Compatibility
Vibration
Shock
Side Load
Operating temperature range
Storage temperature range
Dual Output Hall Effect Sensor
9900 Series
1
2
-90° to +90° (180° total rotation)
1,000Hz minimum
0.025 – 0.110 N-m
35 grams (approx.)
-45° to +45° (other angles available)
5.0 V 0.25V DC
10mA maximum per output
20mA maximum total
0.5V - 4.5V
0.25V – 2.25V
(Different output voltage range for sensor outputs available as a custom option)
Analog (continuous)
100V/meter, 14kHz – 1GHz range
10G peak, 20 – 2,000 Hz
50Gs, half sine pulse, 5 m sec duration
1kg for 1 million cycles
-40°C to +85°C
(wider operating temperature –40° to +150°C available as a custom option)
-55°C to +105°C (-55°C to +165°C)
2.0% of full scale at room temperature
3.0% of full scale over operating temperature range
Connector mates with Packard Electric METRI-Pack
150.2 series (pull-to-seat 6 pin sealed connector
assemblies) (i.e. 12162261, 12162260 or 12162210)
Shaft flat is shown with:
NOTE: All dimensions are shown in millimeters.
sensor 1 output at 50% Vs (input voltage).
sensor 2 output at 25% Vs (input voltage).
ISO9001 Certified/QS9000 Registered
Dual Output Hall Effect Sensor
Vs (input)
GROUND
OUTPUT
9900 Series
(Typical Sensor Output)
CONNECTOR PIN OUTPUT
SENSOR 1
E
C
F
SENSOR 2
B
A
D

Related parts for 9902090 CW