U1253A Agilent Technologies Test Equipment, U1253A Datasheet

no-image

U1253A

Manufacturer Part Number
U1253A
Description
Handheld Digital Multimeter, 50, 000 Count Dual OLED Display, 4.5 Digit Resolutio
Manufacturer
Agilent Technologies Test Equipment
Datasheet
Agilent U1250 Series Handheld
Digital Multimeters
Data Sheet

U1253A Summary of contents

Page 1

... Agilent U1250 Series Handheld Digital Multimeters Data Sheet ...

Page 2

... Offering the same functionality as the U1252A, the U1253A is the world’s fi rst OLED handheld 2 DMM. You won’t have to squint to be sure you’re reading it right: On the the bench, you’ ...

Page 3

... Broad range of measurement functions, including temperature and capacitance Built-in battery charging for optimum capacity [1] U1253A only [2] U1252A/3A only Large numerical display that’s toggleable to dual display mode, both at 50,000- count high resolution 20 MHz frequency counter Data logging to internal or external memory ...

Page 4

... U1251A/U1252A TEMPERATURE SPECIFICATIONS THERMOCOUPLE RANGE TYPE ºC K –200 ~ 1372 ºC J –210 ~ 1200 ºC (for U1252A) U1253A TEMPERATURE SPECIFICATIONS THERMOCOUPLE RANGE TYPE ºC –200 ~ –40 °C K –40 ~1372 °C –210 ~ –40 °C J –40 ~ 1200 °C [1] Input impedance: >1 GW for 50 mV~1000 mV ranges. For U1251A, input impedance (nominal) for 5 V~1000 V ranges. For U1252A/3A, input impedance (nominal) in parallel with 1 ...

Page 5

... V 0.01 V 1000.0 V 0.1 V FUNCTION RANGE RESOLUTION [2] 500.00 µA 5000.0 µA 50.000 mA 0.001 mA AC CURRENT 440.00 mA 5.0000 A 0.0001 A [3] 10.000 A U1252A/U1253A AC SPECIFICATIONS FUNCTION RANGE RESOLUTION 50.000 mV 0.001 mV 500.00 mV 0.01 mV 1000.0 mV 0.1 mV TRUE RMS AC 5.0000 V 0.0001 V VOLTAGE 50.000 V 0.001 V 500.00 V 0.01 V 1000.0 V ...

Page 6

... U1252A/U1253A AC+DC SPECIFICATIONS FUNCTION RANGE RESOLUTION 50.000 mV 0.001 mV 500.00 mV 0.01 mV 1000.0 mV 0.1 mV TRUE RMS AC 5.0000 V 0.0001 V VOLTAGE 50.000 V 0.001 V 500.00 V 0.01 V 1000.00 V 0.1 V FUNCTION RANGE RESOLUTION [3] 500.00 µA 0.01 µA 5000.0 µA 0.1 µA 50.000 mA 0.001 mA AC CURRENT 440.00 mA 0.01 mA 5.0000 A ...

Page 7

... INPUT RANGE (Maximum input for specifi ed accuracy = 10 x Range or 1000 V) 50.000 mV 500.00 mV 1000.0 mV 5.0000 V 50.000 V 500.00 V 1000.0 V U1252A/U1253A FREQUENCY SENSITIVITY DURING VOLTAGE MEASUREMENT INPUT RANGE (Maximum input for specifi ed accuracy = 10 x Range or 1000 V) 50.000 mV 500.00 mV 1000.0 mV 5.0000 V 50.000 V 500.00 V 1000 ...

Page 8

... For signal frequencies greater than 1 kHz, an addition of 0.1% per kHz is added to the accuracy. [5] For data logging to PC, maximum number of data points is dependent on available hard disk space. [6] For the U1253A model. RESOLUTION ACCURACY ± reading + No. of Least Signifi ...

Page 9

... Certifi IEC/EN 61326: 2002, CISPR 11, and equivalents for Group 1, Class A COMMON MODE REJECTION RATIO (CMRR) U1251A/2A: > DC, 50/60 Hz ± 0. unbalanced) U1253A: >100 dB at DC, 50/60 Hz ± 0. unbalanced) NORMAL MODE REJECTION RATIO (NMRR) U1251A/2A: > DC, 50/60 Hz ± 0.1% U1253A: > DC, 50/60 Hz ± 0.1% CREST FACTOR < ...

Page 10

... Certifi cate of Calibration Test Report Quick Start Guide User’s and Service Guide (in Prod- uct Reference CD) U1253A OPTION Option 001 Bundled SMT grabbers, fi ne-tip test probes and soft carrying case OPTIONAL ACCESSORIES MEASURING ACCESSORIES (NON-TEMPERATURE) U1160A Standard test lead kit ...

Page 11

MEASURING ACCESSORIES (TEMPERATURE) U1180A Thermocouple adapter+lead kit, J and K types U1183A Air temperature probe U1186A K-type thermocouple and adapter CABLE U1173A IR-to-USB cable HANGING KIT U1171A Magnetic hanging kit U1181A Immersion temperature probe U1184A Temperature probe adapter CARRYING CASE ...

Page 12

Agilent Email Updates www.agilent.com/fi nd/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confi dence. Remove all doubt Our repair and calibration services will get ...