E3F2-DS10Z2N Omron Automation, E3F2-DS10Z2N Datasheet - Page 22

no-image

E3F2-DS10Z2N

Manufacturer Part Number
E3F2-DS10Z2N
Description
Sensor; Dark-ON; Diffuse Mode Sensing Mode; Photoelectric; 0.1 m; Infrared LED
Manufacturer
Omron Automation
Type
Diffuser
Datasheet

Specifications of E3F2-DS10Z2N

Indicator
Light Incident⁄Power Indicator for Light Source (Red)
Light Source
Infrared LED
Material, Body
Nickel Brass
Material, Cover
Plastic
Material, Lens
PMMA
Primary Type
Photoelectric
Range, Measurement
0.1 In.
Response Time
2.5 ms (Max.)
Sensing Mode
Diffuse
Technology
Photoelectric
Temperature, Operating
-25 to +55 °C
Voltage, Supply
10-30 VDC
Load Rating
DC Models = 100 mA Max., AC Models = 200 mA; 5 V Max.
Circuit Protection
Power Source Reverse Polarity, Output Short-Circuit
Lead Free Status / Rohs Status
RoHS Compliant part
Precautions
The E3F2 Photoelectric Sensor is not a safety component for ensur-
ing the safety of people which is defined in EC directive (91/368/
EEC) and covered by separate European standards or by any other
regulations or standards.
■ Degree of protection
The E3F2 photoelectric sensors have a degree of protection rated
with IP67. In this case, the sensors have passed the OMRON heat
shock test before the IP67-test of IEC 60529 (submersion at 1m
water depth for 30 min). Afterwards the sensors have been tested
according to the OMRON waterproof test.
Heat shock: The Alternating, fast temperature changes between
Water proof: The sensors are submerged alternating in water of
Do not expose the photoelectric sensor to excessive shock during
installation, keeping within IP 67 standards.
■ Wiring
I
same conduit or duct as power lines or high-voltage lines, the photo-
electric sensor could be induced to malfunction, or even be damaged
by electrical noise. Separate the wiring, or use shielded lines as
input/output lines to the photoelectric sensor.
Do not connect the black wire to the brown wire without a load. Direct
connection of these wires may damage the photoelectric sensor (AC
switching type).
22
f the input/output lines of the photoelectric sensor are placed in the
Sensor
+2°C and +55°C. 20 cycles with 1 hour for each tem-
perature are executed. Function, water tightness and
electrical isolation are checked.
-25°C and +55°C are executed for 5 cycles and 1 hour
for each temperature. Function and isolation are
checked.
Photoelectric Sensors
Brown
Black
Blue
Load
24 to 240 VAC
E3F2
When using the photoelectric sensor in the vicinity of an inverter
motor, ensure to connect the protective earth ground wire of the
motor to earth. Failure to ground the motor may result in malfunction
of the sensor.
When you use the photoelectric sensor at temperatures exceeding
45°C, the load current must be within the described values as shown
in the figure below.
■ Installation
Do not exceed a torque of
• 2.0 Nm (20 kgf cm) when tightening mounting nuts for plastic
• 20.0 Nm (200 kgf cm) when tightening mounting nuts for metal
models
models
200
130
0
Operating temperature (˚C)
45