LAN8700C-AEZG SMSC, LAN8700C-AEZG Datasheet - Page 55
LAN8700C-AEZG
Manufacturer Part Number
LAN8700C-AEZG
Description
TXRX ETHERNET 10/100 36-QFN
Manufacturer
SMSC
Type
Transceiverr
Datasheet
1.LAN8700C-AEZG.pdf
(80 pages)
Specifications of LAN8700C-AEZG
Protocol
MII, RMII
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
36-QFN
Product
Ethernet Transceivers
Number Of Transceivers
1
Standard Supported
IEEE 802.3ab
Data Rate
10 Mbps or 100 Mbps
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Supply Current (max)
39 mA, 81.6 mA
Maximum Operating Temperature
+ 85 C
Ethernet Connection Type
10 Base-T, 100 Base-TX
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Drivers/receivers
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
638-1046
638-1046-1
638-1046-1
638-1046-1
638-1046-1
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LAN8700C-AEZG
Manufacturer:
Standard
Quantity:
6 313
Part Number:
LAN8700C-AEZG
Manufacturer:
SMSC
Quantity:
20 000
Company:
Part Number:
LAN8700C-AEZG-C3
Manufacturer:
ROHM
Quantity:
1 638
Part Number:
LAN8700C-AEZG-C3
Manufacturer:
SMSC
Quantity:
20 000
Company:
Part Number:
LAN8700C-AEZG-TR
Manufacturer:
TOSHIBA
Quantity:
24 000
Company:
Part Number:
LAN8700C-AEZG-TR
Manufacturer:
SMSC
Quantity:
1 881
Part Number:
LAN8700C-AEZG-TR
Manufacturer:
SMSC
Quantity:
20 000
±15kV ESD Protected MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX Support and flexPWR
Datasheet
Chapter 6 AC Electrical Characteristics
SMSC LAN8700/LAN8700i
6.1
PARAMETER
Data Out -
Data In -
Clock -
T1.1
T1.2
T1.3
T1.4
MDIO
MDIO
MDC
The timing diagrams and limits in this section define the requirements placed on the external signals
of the Phy.
The Serial Management Interface is used for status and control as described in
Serial Management Interface (SMI) Timing
MDC minimum cycle time
MDC to MDIO (Read from PHY)
delay
MDIO (Write to PHY) to MDC setup
MDIO (Write to PHY) to MDC hold
DESCRIPTION
T
1.3
(Write to PHY)
Figure 6.1 SMI Timing Diagram
Valid Data
Table 6.1 SMI Timing Values
T
1.2
DATASHEET
T
1.4
T
(Read from PHY)
®
55
1.1
Technology in a Small Footprint
Valid Data
MIN
400
10
10
0
TYP
MAX
300
UNITS
ns
ns
ns
ns
Section
Revision 2.2 (12-04-09)
4.13.