HV 44A BK Precision, HV 44A Datasheet - Page 2

no-image

HV 44A

Manufacturer Part Number
HV 44A
Description
Probe; 0 to 40 kV
Manufacturer
BK Precision
Datasheet

Specifications of HV 44A

Voltage, Rating
0 to 40 kVDC
Lead Free Status / Rohs Status
RoHS Exempt Product
DC VOLTS
AC VOLTS
DC CURRENT
AC CURRENT
*10A on for 30 seconds maximum, off for 3 minutes minimum.
RESISTANCE
DIODE CHECK
Measures forward voltage drop of diode or semiconductor junction in mV.
CONTINUITY CHECK
Battery Test
Non-Contact Voltage Indicator
Display
Polarity
Overrange Indication
Measurement Rate
Low Battery Indication
Operating Temperature
Storage Temperature
Power
Battery Life
Dimensions (HxWxD)
Weight
*10A on for 30 seconds maximum, off for 3 minutes minimum.
Ranges
Resolutions
Basic Accuracy
Overvoltage Protection
Input Impedance
Ranges
Resolutions
Basic Accuracy
Input Impedance
Ranges
Resolutions
Basic Accuracy
Overload protection
Ranges
Resolutions
Accuracy
Overload protection
Ranges
Resolutions
Accuracy
Open circuit voltage
Overload protection
Resolution
Accuracy
Open Circuit Voltage
Test Current (approximate)
Overload protection
Buzzer Threshold
Overload protection
Specifications
SUPPLIED: Battery, Test Leads, Instruction Manual
OPTIONAL: TL-2A Deluxe Test Leads, TL-3 Accessory Tip Kit (for TL-2A)
Carrying Case (not included): LC-24
Accessories
TL-130A General Purpose DMM Kit
2V, 20V, 200V, 600V
1mV, 10mV, 100mV, 1V
±(2%rdg+1dgt)
600V, DC + AC Peak
10M
200V, 600V
100mV, 1V
±(2.9%rdg+4dgt), 50Hz-500Hz
10M
200µA, 2mA, 20mA, 200mA, 10A*
0.1µA, 10µA, 100µA, 10mA
±(3.0%rdg+ dgt)
0.8A, 250V fuse; 10A, 600V fused
Does not apply
200 , 2k , 20k , 200k , 20M
100m , 1 , 10 , 100 , 1k
±(2%rdg+3dgt)
approx. 0.3VDC
500V DC + AC Peak
1mV
±(3%rdg+3dgt)
3VDC Typ.
1.0mA ±0.6mA
500V DC + AC Peak
Does not apply
1.5V, 9V
Does not apply
2000 count, 3 1/2 digit 0.53" LCD
Automatic, (-) negative polarity indication
“OL” or “-OL” is displayed
2.5 samples per second
Symbol Displyed
32˚ to 122˚F(0° to + 50°C), <70% R.H
-4˚ to 140˚F(-20° to + 60°C), <70% R.H, battery removed
Single standard 9V battery, NEDA 1604 or equivalent
200 hours typical (alkaline)
5.63 x 2.25 x 1.375" (143 x 68 x 47mm)
7.27 oz. (206g)
2405A
For your nearest distributor, call 800-462-9832 or www.bkprecision.com
Manual ranging, average responding, rms reading
Manual Ranging
Manual ranging
Manual ranging
200mV, 2V, 20V, 600V
100µV, 1mV, 10mV, 1V
±(1.2%rdg+1dgt)
600V, DC + AC Peak
10M
200mV, 2V, 20V, 600V
100µV, 1mV, 10mV, 1V
±(2%rdg+1dgt), 50Hz-500Hz
10M
2mA, 20mA, 200mA, 10A*
0.1µA, 10µA, 100µA, 10mA
±(1.5%rdg+1dgt), ±(3.0%rdg+1dgt) for 20A
0.8A, 250V fuse; 10A, 600V fused
Manual ranging
200µA, 20mA, 200mA, 10A
0.1µA, 10µA, 100µA, 10mA
±(2.0%rdg+4dgt) for 10A
±(3.5%rdg+4dgt)
200 , 20k , 200k , 20M
100m , 10 , 100 , 10k
±(1.5%rdg+4dgt), ±(3.0%rdg+4dgt) for 20M
±(5.0%rdg+5dgt) for 31M
approx. 0.3VDC
500V DC + AC Peak
1mV
±(2.0%rdg+1dgt)
3VDC Typ.
1.0mA
500V DC + AC Peak
<100
500V DC + AC Peak
Does not apply
Detect voltages from 70V to 480VAC
50Hz - 60Hz
2000 count, 3 1/2 digit 0.53" LCD
with 32 segment analog bargraph
2.5 samples per second
2408
Auto/Manual ranging
320mV, 3.2V, 32V, 320V, 600V
100µV, 1mV, 10mV, 100mV, 1V
±(1.2%rdg+1dgt)
600V, DC + AC Peak
10M , 1G
Auto/Manual ranging, average responding,
rms reading
3.2V, 32V, 320V, 600V
1mV, 10mV, 100mV, 1V
±(1.5%rdg+4dgt), 50/60Hz
10M
Auto/Manual ranging
320µA, 3200µA, 32mA, 320mA, 10A*
0.1µA, 1µA, 10µA, 100µA, 10mA
±(2.0%rdg+4dgt,±3.0%rdg+1dgt) fro 20A
0.5A, 250V fuse; 10A, 600V fused
Auto/Manual ranging
320µA, 3200µA, 32mA, 320mA, 10A*
0.1µA, 1µA, 10µA, 100µA, 10mA
±(2.5%rdg+4dgt) 50/60Hz
±(3.5%rdg+1dgt) 50.60Hz for 20A
0.5A, 250V fuse, 10A, 600V
Auto/Manual ranging
320 , 3.2k , 31k , 310k , 3.1M , 31M
100m , 1 , 10 , 100 , 1k , 10k
±(1.0%rdg+3dgt), ±(1.5%rdg+2dgt) for 3.1M
approx. 1.5VDC
500V DC + AC Peak
1mV
±(10%rdg+3dgt)
<3.5VDC
1.0mA ±0.6mA
500V DC + AC Peak
<320
500V DC+AC Peak
Does not apply
Does not apply
3200 count, 3 1/2 digit 0.4" LCD
2 samples per second
2407A
(320mV range only)
One Year Warranty
models
37