UAW500S-24 Cosel U.S.A. Inc., UAW500S-24 Datasheet - Page 2

no-image

UAW500S-24

Manufacturer Part Number
UAW500S-24
Description
Power Supply, Single Output; 85 to 132 VAC; 24 V; 22 A; 528 W (Max.); 50/60 Hz
Manufacturer
Cosel U.S.A. Inc.
Datasheet

Specifications of UAW500S-24

Brand/series
UA Series
Configuration
Enclosed
Current, Output
22 A
Dimensions
140 mm W x 45 mm H x 278 (308) mm D
Frequency, Input
50⁄60 Hz
Mounting Type
Panel
Number Of Outputs
1
Operation
Linear
Output
24 VDC @ 22 A
Power, Output
528 W
Power, Rating
528 W (Max.)
Primary Type
AC-DC
Special Features
Remote Sense
Standards
UL1950, CSA C22.2 No.234, EN60950, VDE0160 Complies with IEC950
Temperature, Operating
-10 to +60 °C
Voltage, Input
85 to 132/170 to 264 VAC
Voltage, Output
24 VDC
Standard Output Voltages
3, 5, 12, 24 and 48, Depending on Model
Auto-ranging Input Voltage
85~132, 170~264 VAC
Built- In Adjustable Output Voltage Potentiometer
±10%
Lead Free Status / Rohs Status
RoHS Compliant part
UAW
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
SPECIFICATIONS
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
The forced air with the fan is necessary.
*1
*2
A-176
RoHS : Please consult us for details
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN:RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
R
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV] 80max
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV] 40max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION 4.00 - 5.25V
OPERATING INDICATION LED ( Green )
REMOTE SENSING
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP. , HUMID.AND ALTITUDE -10 to +60 C , 10 - 90%RH ( Non condensing ) ( Refer to DERATING CURVE ), 3 , 000m ( 10 , 000feet ) max
STORAGE TEMP. , HUMID.AND ALTITUDE -20 to +75 C , 10 - 90%RH ( Non condensing ), 9 , 000m ( 30 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
UAW500S
Unit type
ACIN 100V 12typ ( Io=100% )
ACIN 200V 6.5typ ( Io=100% )
ACIN 100V 15/40typ ( Io=100% ) ( Primary Surge Current/Secondary Surge Current )
ACIN 200V 30/40typ ( Io=100% ) ( Primary Surge Current/Secondary Surge Current )
0 to +50 C
-10 - 0 C
0 to +50 C
-10 - 0 C
* 1
* 1
* 1
* 1
* 2
UAW500S-3
300
3V 100A
UAW500S-3
AC85 - 132 / 170 - 264 1 f ( Auto-selectable )
50/60 ( 47 - 63 )
70typ
0.75max ( 60Hz , According to UL , CSA and VDE )
3
100
40max
100max
120max
120max
180max
12max
800max ( ACIN 85/170V , Io=100% )
10typ ( ACIN 85/170V , Io=100% ) 20typ ( ACIN 100/200V , Io=100% )
Provided
AC3 , 000V 1minute , Cutoff current = 25mA , DC500V 50M W min ( At Room Temperature )
AC2 , 000V 1minute , Cutoff current = 25mA , DC500V 50M W min ( At Room Temperature )
AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( At Room Temperature )
10 - 55Hz , 19.6m/s
196.1m/s
UL60950-1 , CSA C22.2 No.234 , EN60950-1 , EN50178 Complies with IEC60950-1
Complies with FCC-B , CISPR22-B , EN55022-B , VCCI-B
140 X 45 X 278 ( 308 ) mm ( without terminal block ) ( W X H X D ) /2.4kg max , 2.6kg max ( with fan unit )
Forced air
2
( 20G ), 11ms , once each X , Y and Z axis
2
( 2G ), 3minutes period , 60minutes each along X , Y and Z axis
UAW500S-5
500
5V 100A
UAW500S-5
77typ
5
100
40max
80max
100max
120max
120max
180max
50max
20max
+10% , -5%
Works at 115 - 140% of rating
1
Ordering information
UA
2
W
UAW500S-12
516
12V 43A
UAW500S-12
80typ
12
43
80max
120max
120max
150max
150max
200max
160max
48max
3
500
4
S
UAW500S-24
528
24V 22A
UAW500S-24
83typ
24
22
100max
160max
120max
150max
150max
200max
200max
96max
1Series name
2Autoranging input
3Output wattage
4Single output
5Output voltage
6Optional
C :with Coating
F :with Fan unit
G :Low leakage current
5
-5
6
-O

Related parts for UAW500S-24