G9SA-321-T075 AC/DC24 Sti (Scientific Technologies, Inc.), G9SA-321-T075 AC/DC24 Datasheet - Page 5

no-image

G9SA-321-T075 AC/DC24

Manufacturer Part Number
G9SA-321-T075 AC/DC24
Description
Safety Monitoring Relay, 3NO immediate, 2NO delayed, 7.5 sec
Manufacturer
Sti (Scientific Technologies, Inc.)
Datasheet

Specifications of G9SA-321-T075 AC/DC24

Lead Free Status / Rohs Status
RoHS Compliant part
Wiring of Inputs and Outputs
*1. Terminal T23
*2. Output Contacts
*3. Terminals A and B
Power supply input
Safety input 1
Safety input 2
Feedback/reset input
Instantaneous safety outputs
OFF-delayed safety outputs
Auxiliary output
Manual/Auto selector input
Ground terminal
Terminal T23 is used for 2-channel input with a positive common (when connecting a safety sensor with a PNP output). When T23 is being
used, please open T21 and T22. For 1-channel input, short circuit T12-T23 before use.
G9SA-301: Safety Output Contacts 13-14, 23-24, 33-34. Auxiliary Contact 41-42.
G9SA-501: Safety Output Contacts 13-14, 23-24, 33-34, 43-44, 53-54. Auxiliary Contact 61-62.
G9SA-321-T@: Safety Output Contacts 13-14, 23-24, 33-34. Safety OFF-delay Output Contact 43-44, 53-54. Auxiliary Contact 61-62.
A-B Opening: Manual Reset
A-B Short Circuit: Auto Reset
Signal name
A1, A2
T11, T12
T21, T22, T23 *1
T31, T32
See below. *2
See below. *2
See below. *2
A, B *3
PE
Terminal name
The input terminals for power supply. Connect the power source to the A1 and A2 terminals.
DC inputs have polarity, so A1 should be connected to the positive side and A2 to the negative side.
To set the safety outputs in the ON state, the ON state signals must be input to both safety input 1 and
safety input 2. Otherwise the safety outputs cannot be in the ON state.
To set the safety outputs in the ON state, the ON state signal must be input to T31 - T32. Otherwise the
safety outputs cannot be in the ON state.
Turns ON/OFF according to the state of the safety inputs and feedback/reset inputs. During OFF-delay
state, the Instantaneous safety outputs are not able to turn ON.
OFF-delayed safety outputs. The OFF-delay time is set by the OFF-delay preset switch.
Synchronized with Instantaneous Safety Output.
Switch between Auto Reset and Manual Reset modes.
Be sure to connect the PE terminal to a protective earth for 100-240 VAC models.
Where the 24 VAC/VDC model power supply is not grounded, lease be sure to connect the PE to a
protective earth.
Description of operation
G9SA
5