U1253B Agilent Technologies Test Equipment, U1253B Datasheet
U1253B
Specifications of U1253B
U1253B Summary of contents
Page 1
... The series’ latest multimeters, the U1251B, U1252B and U1253B come in vivid orange cases, offering capabilities and functions equivalent to the U1250A Series. Key features ...
Page 2
... Built-in battery charging for optimum capacity [1] U1253A/U1253B only [2] U1252A/U1252B/U1253A/U1253B only 50,000 count dual display with true- RMS reading capability Figure 2: U1253B front view 2 20 MHz frequency 2 counter Data logging to internal or external memory Programmable square-wave generator for stimulation of 2 ...
Page 3
DC SPECIFICATIONS FUNCTION RANGE 50.000 mV 500.00 mV 1000.0 mV VOLTAGE (1) 5.0000 V 50.000 V 500.00 V 1000.0 V 500.00 W [3] 5.0000 kW [3] 50.000 kW 500.00 kW RESISTANCE (8) 5.0000 MW [4] 50.000 MW [4] 500.00 MW ...
Page 4
... FUNCTION RANGE [4] 500.00 µA 5000.0 µA 50.000 mA AC CURRENT [2] 440.00 mA 5.0000 A 10.000 A [5] U1252A/U1252B/U1253A/U1253B AC SPECIFICATIONS FUNCTION RANGE 50.000 mV 500.00 mV 1000.0 mV TRUE RMS AC 5.0000 V VOLTAGE [1] [2] [8] 50.000 V 500.00 V 1000.0 V FUNCTION RANGE 500.00 µA [4] 5000.0 µA 50.000 mA TRUE RMS AC CURRENT [2] [8] 440.00 mA 5.0000 A [5] 10 ...
Page 5
... A 10.000 A [6] U1251A/U1251B/U1252A/U1252B TEMPERATURE SPECIFICATIONS THERMOCOUPLE RANGE TYPE ºC K –200 ~ 1372 ºC J –210 ~ 1200 ºC (for U1252A/U1252B) U1253A/U1253B TEMPERATURE SPECIFICATIONS THERMOCOUPLE RANGE TYPE ºC –200 ~ –40 °C K –40 ~1372 °C –210 ~ –40 °C J –40 ~ 1200 °C CAPACITANCE SPECIFICATIONS RANGE 10.000 nF 100 ...
Page 6
... INPUT RANGE (Maximum input for specifi ed accuracy = 10 x Range or 1000 V) 50.000 mV 500.00 mV 1000.0 mV 5.0000 V 50.000 V 500.00 V 1000.0 V U1252A/U1252B/U1253A/U1253B FREQUENCY SENSITIVITY DURING VOLTAGE MEASUREMENT INPUT RANGE (Maximum input for specifi ed accuracy = 10 x Range or 1000 V) 50.000 mV 500.00 mV 1000.0 mV 5.0000 V 50.000 V 500.00 V 1000 ...
Page 7
... Hz 9.9999 kHz 99.999 kHz 999.99 kHz 9.9999 MHz 100 9.9999 MHz (secondary display “-100-“) 99.999 MHz U1252A/U1252B/U1253A/U1253B SQUARE WAVE OUTPUT [2] OUTPUT FREQUENCY 0. 75, 80, 100, 120, 150, 200, 240, 300, 400, 480, [3] DUTY CYCLE PULSE WIDTH [4] AMPLITUDE MINIMUM SENSITIVITY (R ...
Page 8
... For signal frequencies greater than 1 kHz, an addition of 0.1% per kHz is added to the accuracy. [5] For data logging to PC, maximum number of data points is dependent on available hard disk space. [6] For the U1253A/U1253B model. INPUT IMPEDANCE Table A ...
Page 9
... Certifi IEC/EN 61326: 2002, CISPR 11, and equivalents for Group 1, Class A COMMON MODE REJECTION RATIO (CMRR) U1251A/U1251B/U1252A/U1252B: > DC, 50/60 Hz ± 0. unbalanced) U1253A/U1253B: >100 dB at DC, 50/60 Hz ± 0. unbalanced) NORMAL MODE REJECTION RATIO (NMRR) U1251A/U1251B/U1252A/U1252B: > DC, 50/60 Hz ± 0.1% U1253A/U1253B: > DC, 50/60 Hz ± 0.1% TEMPERATURE COEFFICIENT ...
Page 10
... U1162A Alligator clips • One pair of insulated alligator clips (red and black). Recommended for use with Agilent standard test leads. • Rated CAT III 1000 U1253B • – – • • – – • – • ...
Page 11
U1163A SMT grabbers • One pair of SMT grabbers (red and black). Recommended for use with Agilent standard test leads. • Rated CAT II 300 MEASURING ACCESSORIES (NON-TEMPERATURE) U1168A Standard test lead kit Includes two test leads ...
Page 12
MEASURING ACCESSORIES (TEMPERATURE) U1186A K-type thermocouple and adapter • T/C adapter J/K-type • T/C bead J-type: –20 °C to 200 °C CABLE U1173A IR-to-USB cable • For remote control and data logging to PC • Max. baud rate: 19,200 bits ...
Page 13
Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners ...