Relay; SSR; Industrial; Cur-Rtg 10A; Ctrl-V 32DC; Vol-Rtg 250AC; Chassis Mnt; Screw
Manufacturer
TELEDYNE
Datasheet

Specifications of 601-2

Brand/series
601 Series
Current, Leakage, Off-state
9.0 mA (RMS) (Max.) @ 250 V (RMS)
Current, Rating
10 A
Current, Surge
1000% (Max.)
Dielectric Strength
1500 VAC (Min.)
Dimensions
1 in. L x 0.9 in. (Max.) W x 2 in. H
Function
General Purpose
Mounting Type
Panel
Relay Type
Solid State
Temperature, Ambient, Maximum
+80 °C
Temperature, Ambient, Minimum
-40 °C
Termination
Screw
Transient Overvoltage
500 Vpeak (Min.)
Voltage, Control
32 VDC
Voltage, Rating
250 VAC
Load Voltage Rating
Output Current Rating
Frequency Range
Over Voltage Range
On-State Voltage Drop
(@ Rated Current)
Surge Current Rating (16 ms)
(See Figure 6 and Note 4)
Turn-On Time
Turn-Off Time
Off-State Leakage @ 250 Vrms
Off-State dv/dt (See Note 1) 200
Capacitance (Input to Output)
Operating Temperature
Storage Temperature
Junction Temperature (T
Dielectric Strength
Isolation
Thermal Resistance
NOTES
1. Output transient (dv/dt) protection is provided in all models
2. For any mounting conditions: 5-amp relays,
3. Basic part number provides screw terminals or PC board
4. Triac may lose blocking capability during and after surge
5. Relays mounted with silicone grease on heat sink such as
and they are designed to switch resistive or inductive loads
to 0.2 power factor. The dv/dt rating is based on a source
impedance of 50 ohms.
For 10-amp relays,
pins (Figure 1). For single 1/4-inch quick disconnect
terminals, add suffix ‘Q” to 10-amp part numbers, or “QQ”
suffix for double 1/4-inch quick disconnects. (Examples:
601-2Q, 601-2QQ).
until T(J) falls below maximum.
Astrodyne, Inc., Type 2518-0500-A00B (for 1.0°C/W).
601-1
601-2
601-1, -2
601-1H, -2H
JA
JS
) 601-1
) 601-2
ENVIRONMENTAL SPECIFICATIONS
OUTPUT (LOAD) SPECIFICATIONS
θ
JS
= 4.8°C/W.
J
)
1500
Min
500
600
Min
–40
–40
0.1
0.1
10
47
9
1000
Max
10.0
70.0
15.0
Max
19.0
+80
+80
250
125
5.0
4.0
0.5
1.0
9.0
4.8
θ
JA
= 19°C/W.
mArms
Vpeak
Vpeak
Ohms
Units
Cycle
Cycle
Units
Vrms
Arms
Arms
Vrms
°C/W
°C/W
V/µs
Vac
Hz
pF
°C
°C
°C
%
Figure 6 – Maximum surge as function of load voltage
Figure 3 – Typical input current vs. control voltage
12
10
1000
8
6
4
2
0
800
600
400
200
6
5
4
3
2
1
0
12
10
0
8
6
4
2
0
0
10
0
Figure 4 – Maximum load current vs.
Figure 5 – Maximum load current vs.
MOUNTED ON 1.0˚C/W HEAT SINK (SEE NOTE 5)
10
CHARACTERISTICS CURVES
10
ambient temperature 601-1
ambient temperature 601-2
5
SURGE DURATION (ms) - NON-REPETITIVE
20
20
AMBIENT TEMPERATURE (˚C)
AMBIENT TEMPERATURE (˚C)
10
30
30
CONTROL VOLTAGE (Vdc)
100
40
40
15
50
50
20
60
60
1000
Series 601
25
70
70
80
30
80
601\072002\Q1
90
10000
90
35

Related parts for 601-2