GLC40DG SL Power ( Ault / Condor ), GLC40DG Datasheet

no-image

GLC40DG

Manufacturer Part Number
GLC40DG
Description
POWER SUPPLY, SWITCHING; 1.3 A (MAX.); 37 A (MAX.); 20 MS; 0 TO 50 DEGC
Manufacturer
SL Power ( Ault / Condor )
Type
Commercialr
Datasheet

Specifications of GLC40DG

Brand/series
GLC40 Series
Configuration
Open-Frame
Mounting Type
Panel
Number Of Outputs
3
Operation
Switching
Output
-12 VDC @ 0.4 A, +5 VDC @ 3 A, +24 VDC @ 1 A
Power, Output
40 W
Primary Type
AC-DC
Voltage, Input
90 to 264 VAC
Voltage, Output
-12, +5, +24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
24
GLC40 Commercial
40 Watt Global Performance Switchers
SPECIFICATIONS:
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated
output load not to exceed 1.3 A.
Output Power
Normal continuous output power is 40 W for unrestricted
natural convection cooling, 45 W peak for 60 seconds.
During peak load conditions output regulation may
exceed total regulation and noise limits.
Output Regulation
Regulation for multiple-output models measured by
±40% load change from 60% rated load with all other
outputs at 60% full rated load and a line voltage change
from low line to high line. Initial set tolerance is measured
with all outputs at 60% of full rated load. Output voltage
V1 requires 20% load for proper regulation of multiple-
output models. Regulation for single-output models
measured by changing from 5% to 50% load or 50% load
to full load in either direction.
Power Limit
Factory set to begin power limiting at approximately 55 W.
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
mode. Measured with noise probe directly across output
terminals of the power supply.
Transient Response
Main Output: 500 µs typical response time for return to
within 0.5% of final value for a 50% load step change, i/
shutdown overshoot less than 3%.
Overvoltage Protection
Built in on V1 with firing point set per table. OVP firing
reduces output #1 and #2 to less than 50% of nominal
voltage in 50 ms.
t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/
Voltage Adjust
Factory set on standard unit; however, optional
potentiometer adjusts voltage from 4.7 V to OVP point
(6.2 V nominal) on the +5 V output.
Efficiency
70% typical depending on model.
Turn-on Time
Less than 1 second at 120 Vac, 25°C (inversely
proportional to input voltage and thermistor temperature).
Input Protection
Internal ac fuse provided on all units. Designed to blow
only if a catastrophic failure occurs in the unit. Fuse does
not blow on overload or short circuit.
Inrush Current
Inrush limited by internal thermistors. Inrush at 240 Vac,
averaged over the first ac half-cycle under cold start
conditions will not exceed 37 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Safety
All GLC models are approved to UL1950, CSA-C22.2 No.
234 Level 3, IEC950 and EN60950.
FEATURES:
• Cost-effective power source
• Universal input 90-264 Vac
• 2-year warranty
• Single and multiple outputs
• Overload and overvoltage protection
• Built-in EMI filter
• UL1950, CSA-C22.2 No. 234 Level 3,
• Operation at no-load
IEC950 and EN60950
marked to LVD
EN55022 Class A; FCC Class A
COMPLIANCE LEVEL
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.