PTF14A Omron Automation, PTF14A Datasheet - Page 4

no-image

PTF14A

Manufacturer Part Number
PTF14A
Description
SOCKET; RELAY; 4 POLE; 35MM DIN RAIL/PANEL MOUNT; FOR OMRON LY SERIES
Manufacturer
Omron Automation
Datasheet

Specifications of PTF14A

Mounting Type
Track
Number Of Poles
4
Termination
Socket
For Use With
LY Type Relay
3-pole Type – AC
3-pole Type – DC
4-pole Type – AC
4-pole Type – DC
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%, -20% for AC rated
6
12
24
50
100/110
120
200/220
240
6
12
24
48
100/110
6
12
24
50
100/110
120
200/220
240
6
12
24
48
100/110
voltage (V)
voltage (V)
voltage (V)
voltage
Rated
Rated
Rated
Rated
(V)
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23°C (73°F).
4. Class B coil insulation is available.
current, and ±15% for DC rated coil resistance.
310
159
80
38
15.90/18.30 13.60/15.60 2,300
17.30
10.50/11.60 9.00/9.90
9.40
234
112
58.60
28.20
12.70/13
386
199
93.60
46.80
22.50/25.50 19/21.80
19.00
11.50/13.10 9.80/11.20
11.00
240
120
69
30
15/15.90
Rated current (mA)
Rated current (mA)
Rated current (mA)
Rated current (mA)
50 Hz
50 Hz
270
134
67
33
14.8
8
330
170
80
40
16.40
9.50
60 Hz
60 Hz
6.70
24
100
410
2,450
8,650
10,400
25.70
107
410
1,700
8,500
5
20
78
350
1,800
2,200
6,700
9,000
25
100
350
1,600
6,900
resistance
resistance
resistance
resistance
Coil
Coil
Coil
Coil
(Ω)
(Ω)
(Ω)
(Ω)
0.03
0.12
0.44
2.24
10.50
11.50
34.80
38.60
0.11
0.45
1.89
8.53
29.60
0.02
0.10
0.38
1.74
10.50
9.30
33.10
33.20
0.09
0.39
1.41
6.39
32
Armature
Armature
Armature
Armature
OFF
OFF
OFF
OFF
Coil inductance
Coil inductance
Coil inductance
Coil inductance
(ref. value) (H)
(ref. value) (H)
(ref. value) (H)
(ref. value) (H)
0.05
0.21
0.79
3.87
18.50
20.60
59.50
74.60
0.21
0.98
3.87
13.90
54.30
0.04
0.17
0.67
2.88
17.30
19
57.90
63.40
0.21
0.84
2.91
13.60
63.70
Armature
Armature
Armature
Armature
ON
ON
ON
ON
80% max.
80% max.
80% max.
80% max.
Pick-up
Pick-up
Pick-up
Pick-up
voltage
voltage
voltage
voltage
(% of rated voltage)
(% of rated voltage)
(% of rated voltage)
General Purpose Relay
30% min.
10% min.
30% min.
10% min.
Dropout
Dropout
Dropout
Dropout
voltage
voltage
voltage
voltage
(% of rated voltage)
110%
110%
110%
110%
Maximum
Maximum
Maximum
Maximum
voltage
voltage
voltage
voltage
LY
Approx.
1.60 to 2.00
(60 Hz)
Approx.
1.40
Approx.
1.95 to 2.50
(60 Hz)
Approx.
1.50
consumption
consumption
consumption
consumption
(VA, W)
(VA, W)
(VA, W)
(VA, W)
Power
Power
Power
Power
4