AD960-24 Cosel U.S.A. Inc., AD960-24 Datasheet - Page 2

no-image

AD960-24

Manufacturer Part Number
AD960-24
Description
Power Supply; 170 to 264 VAC/240 to 370 VDC; 24 V; 40 A; 960 W (Max.)
Manufacturer
Cosel U.S.A. Inc.
Datasheet

Specifications of AD960-24

Brand/series
AD Series
Configuration
Enclosed
Current, Output
40 A
Dimensions
89 mm W x 141.6 mm H x 230 mm D
Frequency, Input
47 to 440 Hz
Mounting Type
Panel
Number Of Outputs
1
Operation
Linear
Output
24 VDC @ 20 A
Power, Output
960 W
Power, Rating
960 W (Max.)
Primary Type
AC-DC
Standards
UL1950, CSA C22.2 No.234, EN60950, VDE0160 Complies with IEC950
Temperature, Operating
-10 to +65 °C
Voltage, Input
85 to 132/240 to 370 VAC/VDC
Voltage, Output
24 VDC
Output Voltage
24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
AD
INPUT
OUTPUT
PROTECTION
CIRCUIT
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
SPECIFICATIONS
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
Please refer to derating curve, because the rated load current depends
on cooling method that is convention cooling or forced air.
*1
*2
*3
*
A-140
RoHS : Please consult us for details
For convection cooling, peak current for 10 seconds or less is acceptable, and output current must be less than 20A on average.
Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
When operated at pulse load, attach external capacitor at output line which is complying with the peak value of pulse current.
R
MODEL
VOLTAGE[V]
FREQUENCY[Hz]
EFFICIENCY[%]
INRUSH CURRENT[A] ACIN 200V 60typ ( Io=100% )
LEAKAGE CURRENT[mA] 1.0max ( 60Hz , According to UL , CSA , VDE and DEN-AN )
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV] 340max
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p] -10 to +45 C
TEMPERATURE REGULATION[mV] -10 to +45 C 420max
DRIFT[mV]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 22.8 - 26.4
START-UP TIME[ms]
HOLD-UP TIME[ms]
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION Works at 115 - 140% of rating
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP. , HUMID.AND ALTITUDE -10 to +65 C , 10 - 90%RH ( Non condensing ) ( Refer to DERATING CURVE ), 3 , 000m ( 10 , 000feet ) max
STORAGE TEMP. , HUMID.AND ALTITUDE -20 to +75 C , 10 - 90%RH ( Non condensing ), 9 , 000m ( 30 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
AD960
Unit type
Forced air 40
Convection
-10 to +45 C
Forced air 24V 40A
Convection 24V 20 ( Peak 40 ) A
* 1
* 2
* 2
* 3
AD960-24
960
AD960-24
AC170 - 264 1 f or DC240 - 370
47 - 440 or DC
85typ
24
20 ( Peak 40 )
200max
240max
480max
100max
600max ( ACIN 200V , Io=100% )
15typ ( ACIN 200V , Io=100% )
AC3 , 000V 1minute , Cutoff current = 25mA , DC500V 50M W min ( At Room Temperature )
AC2 , 000V 1minute , Cutoff current = 25mA , DC500V 50M W min ( At Room Temperature )
AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( At Room Temperature )
10 - 55Hz , 19.6m/s
196.1m/s
UL60950-1 , CSA C22.2 No.234 , EN60950-1 , VDE0160 Complies with IEC950
Complies with FCC-A
89 X 141.6 X 230mm ( without terminal block ) ( W X H X D ) /3.0kg max
Forced air/Convection
2
( 20G ), 11ms , once each X , Y and Z axis
2
( 2G ), 3minutes period , 60minutes each along X , Y and Z axis
1
Ordering information
AD
2
960
AD960-30
960
30V 32A
30V 16 ( Peak 32 ) A
AD960-30
85typ
30
32
16 ( Peak 32 )
260max
420max
240max
480max
520max
120max
28.5 - 33.0
3
-24
1Series name
2Output wattage
3Output voltage