ZC-N2255 Omron Automation, ZC-N2255 Datasheet - Page 3

no-image

ZC-N2255

Manufacturer Part Number
ZC-N2255
Description
Switch, Limit, Enclosed, Sealed Roller Plunger
Manufacturer
Omron Automation
Type
Limitr
Datasheet

Specifications of ZC-N2255

Actuator Type
Roller Plunger
Contact Form
SPDT
Current, Rating
10 AAC/ADC
Dielectric Strength
1000/2000 VAC
Ip Rating
IP67
Mounting Hole Size
4.3 mm
Mounting Type
Panel
Number Of Poles
1
Operation
Snap Action
Special Features
Sealed
Temperature, Operating
-10 to 80 °C
Termination
Screw/Crimp
Voltage, Rating
250 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Operating characteristics
Applicable standard (UL)
Applicable standard (CSA)
Applicable standard (TUV)
Applicable standard (CCC(CQC))
Applicable standard (EC Directive (Low Voltage
Directive))
Mounting specification
Operating Force (OF)
Release Force (RF)
Pre-Travel (PT)
Over-Travel (OT)
Movement Differential (MD)
Operating Position (OP)
Precautions for correct use:
To attach the protective cover to the case, hold the cover in almost parallel to the case and then push it to the case. If
the cover is pushed diagonally, the rubber packing may slip off and degrading the seal ability of the switch.
Note:
Rubber material is oil-proof rubber(NBR). Cap-rubber is made from weather-proof rubber(Chloroprene rubber).
Standard value 6.86 N Max.
Standard value 1.67 N Min.
Standard value 1.5 mm Max.
Standard value 2.5 mm Min.
Standard value 0.2 mm Max.
Standard value 47.4 +/- 0.8 mm
Standard No.: UL508
File number: E76675
Standard No.: C22.2 NO.14
File number: LR45746
Standard No.: EN60947-5-1
File number: J50041904
Standard No.: GB14048.5
File number: 2003010303077620
2006/95/EC
Side mounting