H3DE-S1 AC/DC24-230 Omron Automation, H3DE-S1 AC/DC24-230 Datasheet
H3DE-S1 AC/DC24-230
Specifications of H3DE-S1 AC/DC24-230
Related parts for H3DE-S1 AC/DC24-230
H3DE-S1 AC/DC24-230 Summary of contents
Page 1
... Item Mounting track End plate Spacer Part number Multifunctional Standard H3DE-M2 DC12 — H3DE-M2 AC/DC24-230 H3DE-S2 AC/DC24-230 H3DE-M1 AC/DC24-230 H3DE-S1 AC/DC24-230 2. 1: SPDT 3. Supply voltage 2: DPDT Description Part number 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N (t) PFP-100N2 ...
Page 2
... Timer with a solid-state output such as a sensor. 3. The power consumption is for mode A (ON-delay) after the Timer counts the time-up time and for the AC input at 50 Hz. The power consumption of the H3DE-Mj includes the input circuit with the B1 and A1 terminals short-circuited. 2 ...
Page 3
... IP30 (Terminal block: IP20) Weight 120 g Note: 1. With the H3DE-Mj, if the voltage exceeds 26.4 VAC/DC, the following hold at signal OFF for C, D, and G modes: Accuracy of operating time: ±1% ±50 ms max. at 1.2-s range Setting error: ±10% +100/- -50 ms max. Signal input time: 100 ms min. ...
Page 4
... Output indicator (orange) (Lit while Timer gives output.) Operating mode selector (select a mode from B2 and G for the H3DE-M1/-M2, from and B2 for the H3DE-S1/S2) Power-on indicator (green) (Lit while the power is on.) Bottom View Output type selector switch for H3DE-M2/-S2 (default setting ...
Page 5
... Time range/ Operating unit selectors mode selector Counting Output circuit circuit Indicator Input circuit circuit Power-ON Output indicator indicator Time range/ Operating unit selectors mode selector Counting Output circuit circuit Indicator circuit Power-ON Output indicator indicator H3DE-S1/-S2 No input is available. 5 ...
Page 6
... The H3DE-M/-S can be set to any one of the operating modes Turn the operating mode selector with a screwdriver until the desired operating mode ( for the H3DE-M and A, B2 for the H3DE-S) appears in the operating mode display window located below the selector. J TIMING CHART Note: 1. The minimum power reset time is 0.1 s and the minimum signal input time is 0. The letter “ ...
Page 7
... Note.) Output relay and 16 (25 and 26) Output relay: NO (output indicator) 15 and 18 (25 and 28) Power indicator Note: The start input of the H3DE-M1 or H3DE-M2 model is activated by applying a voltage to B1 and A2 terminals. The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement ...
Page 8
... Approx. Output relay: NO 1±0.6 s (output indicator) (fixed) 15 and 18 (25 and 28) Power indicator Note: The start input of the H3DE-M1 or H3DE-M2 model is activated by applying a voltage to B1 and A2 terminals. The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement ...
Page 9
... H3DE-S Installation J TERMINAL ARRANGEMENT Note: 1. The contact symbol for the H3DE is indicated with the delayed contact for conventional timers supply voltage does not require the designation of polarity. 3. The relay R2 can be set to either instantaneous or time-limit contact using the switch located on the bottom of the Timer. ...
Page 10
... J INPUT CONNECTIONS The inputs of the H3DE-M1/-M2 are voltage (voltage imposition or open) inputs. No-Contact Input Connection to PNP output sensor. Sensor Timer (+) 1 Start 24 VDC (- -) A 2 Operates with PNP transistor ON Voltage Input Signal Levels 1. Transistor ON No-contact input Residual voltage max.; voltage between terminals B “H-level” voltage (20.4 VDC min.) 2. Transistor OFF Leakage current: 0.01 mA max. ...
Page 11
... When removing the H3DE, pull out portion (C) with a flat-blade screwdriver and remove the Timer from the mounting track. (A) The H3DE can be mounted or removed easily if a distance (1.18 in) or more is kept between the H3DE and the top surface of other equipment located below the H3DE. (B) H3DE 16 35± ...
Page 12
... Timer. Both AC and DC power supplies can be connected to the power input terminals without regarding polarity. With the H3DE only power supply must be connected to the power input terminals as designated according to the polarity of the terminals power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer ...
Page 13
... J VDE CONFORMANCE The H3DE as a built-in timer conforms to VDE 0435/P2021 provided that the following conditions are satisfied: The output section of the H3DE is provided only with basic isolation. To ensure reinforced isolation required by the VDE standards, provide supplementary basic isolation on the load side connected to the output ...
Page 14
... One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC TMCN1 3/02 J RELAY LIFE EXPECTANCY Built-in relay for the H3DE: G6RN; 50,000 operations min 250 VAC, resistive load at 360 operations/h.) OMRON ON- -LINE Global - - http://www.omron.com USA - - http://www.omron.com/oei Canada - - http://www.omron.com/oci Specifications subject to change without notice. ...