E2E-X5MF1-M1 Omron Automation, E2E-X5MF1-M1 Datasheet - Page 13

no-image

E2E-X5MF1-M1

Manufacturer Part Number
E2E-X5MF1-M1
Description
Sensor, Proximity; Inductive Sensing Mode; M12; PNP; 5 mm; 200 mA (Max.)
Manufacturer
Omron Automation
Type
Inductiver
Datasheet

Specifications of E2E-X5MF1-M1

Body Style
Cylindrical
Current, Rating
200 mA (Max.)
Current, Switching
200 mA
Frequency
0.4 kHz (Response)
Function
Proximity
Ip Rating
IP67
Mounting Style
Flush Mount
Mounting Type
M12 Threaded
Output
PNP
Primary Type
Proximity
Range, Measurement
5 mm
Standards
IEC Approved, NEMA Approved
Technology
Inductive
Temperature, Operating
-40 to 85 °C
Termination
Connector
Vibration
10 to 55 Hz
Voltage, Supply
24 VDC
Voltage, Switching
3 V
Lead Free Status / Rohs Status
RoHS Compliant part
I/O Circuit Diagrams
E2E-X@D@ DC 2-Wire Models
diagnostic
diagnostic
diagnostic
Operation
With self-
Without
Without
output:
output:
output:
mode
self-
self-
NO
NC
NO
E2E-X@D1-N
E2E-X@D1-M1G(J)
E2E-X@D1-(M1TGJ)-U
E2E-X@D1-M3G
E2E-X@D1-M1J-T
E2E-X@D2-N
E2E-X@D2-M1G
E2E-X@D2-(M1TGJ)-U
E2E-X@D2-M3G
E2E-X@D1S
E2E-X@D1S-M1
Model
The diagnostic output is ON when there is a coil
burnout or the sensing object is located in the
unstable sensing area for 0.3 s or longer.
Non-sensing
Non-sensing
Sensing
object
Sensing
object
(%)
Sensing
object
(%)
(%)
Non-sensing
area
area
area
Rated
sensing
distance
Rated
sensing
distance
Rated
sensing
distance
Unstable
sensing
area
Unstable
sensing
area
100
100
100
Timing Chart
80
Sensing area
80
Set position
Set position
Stable sensing area
Stable sensing area
0
0
ON
OFF
ON
OFF
0
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Proximity Sensor
Proximity Sensor
Proximity Sensor
Operation
indicator (red)
Control output
Setting indicator
(green)
Operation
indicator (red)
Control output
Diagnostic output
Setting indicator
(green)
Operation
indicator (red)
Control output
Polarity: Yes
Polarity: None
Note 1. The load can be connected to either the +V or
Note: The load can be connected to either the +V
Note: The load can be connected to either the
Note: Connect both the loads to the +V side of
Prox-
imity
Sensor
main
circuit
Prox-
imity
Sensor
main
circuit
Prox-
imity
Sensor
main
circuit
2. The E2E-X@D1-M1J-T has no polarity.
Prox-
imity
Sensor
main
circuit
or 0 V side.
+V or 0 V side.
the control output and diagnostic output.
0 V side.
Therefore, terminals 3 and 4 have no polarity.
Output circuit
Brown (4)
Blue (3)
Orange (2)
(diagnostic
output)
Brown
Blue
1
4
4
Brown
2
3
Blue
1
Load
Load
Load
Load
Load
0 V
+V
(0 V)
(+V)
0 V
+V
0 V
+V
+V
+V
0
E2E
16

Related parts for E2E-X5MF1-M1