H7CX-A-N AC100-240 Omron Automation, H7CX-A-N AC100-240 Datasheet - Page 16

no-image

H7CX-A-N AC100-240

Manufacturer Part Number
H7CX-A-N AC100-240
Description
Counter, Digital, Six Digit, Multifunction, 1/16 Din, 100-240VAC, Screw Terminal
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CX-A-N AC100-240

Brand/series
H7CX
Connection Type
Screw Terminals
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
100-240 VAC
16
H7CX-A@-N
Counter
From next page
Change to Function Setting Mode.
Step3
*1 If the mode is switched to the function setting mode during operation, operation will continue.
*2 Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also,
when settings are changed, the counter is reset (present value initialized and output turned OFF) on returning to run mode.
Run mode
Power ON
To next page
Parameters that cannot be set with the DIP switch are set with the operation keys on the front panel.
Input mode
(CNTM)
Output mode
(OUTM)
Output
time
(OTIM)
Counting
speed
(CNTS)
Prescale
value
(PSCL)
NPN/PNP
input mode
(IMOD)
Display color
(COLR)
Reset input
signal width
(IFLT)
Decimal
point position
(DP)
3 s min.
3 s min.
*3
*7
setting mode
*1
*2
Function
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated by
For 6-digit models, only U Keys are provided.
Displays for 6-digit models are given in parentheses.
• Set the input mode using the U (D) Keys.
*5 Displayed for output modes other than K-2, D, L, and H only.
Note: Displayed only when Twin Counter Mode is not selected.
• Set the output mode using the U (D) Keys.
*6 Displayed only when the input mode is ud-a, ud-b, or ud-c.
• Set each digit using the individual U (D) Keys.
Note: Displayed only when the output mode is C, R, K-1, P, Q, A,
• Set the Reset input signal width using the U (D) Keys.
• Set the counting speed using the U (D) Keys.
• Set each digit using the individual U (D) Keys.
• Set the NPN/PNP input mode using the U (D) Keys.
• Set the display color using the U (D) Keys.
• Set the decimal point position using the U (D) Keys.
(NPN input)
Note: Displayed for terminal-block models (except H7CX-A11@) only.
(Not displayed when the function is set to twn.)
(0.01 s)
(N)
(30 Hz)
(20 ms)
(0.001)
(Red)
0.001
(UP)
n
0.01
30hz
20ms
(No decimal point)
npn
red
up
or K-2.
*5
(F)
(0.50 s) (99.99 s)
f
0.50
(PNP input)
(DOWN) (UP/DOWN A) (UP/DOWN B) (UP/DOWN C)
(Green) (Orange) (Red-green) (Green-red) (Red-orange) (Orange-red) (Green-orange) (Orange-green)
down
pnp
grn
(1 ms)
1.000
(5 kHz)
1ms
(1.000)
For details on operations and display in run mode, refer to page page 20.
The display depends on the selected configuration.
(C)
c
99.99
org
(R)
r
ud-a
9.999
(One digit after
(9.999)
decimal point)
(K-1)
k-1
r-g
99.999
(99.999)
ud-b
(P)
p
g-r
(Q)
q
ud-c
(Two digits after
decimal point)
r-o
(A)
a
k-2
(K-2)
o-r
*6
(D)
*7 Set each digit using the individual U (D) Keys.
d
*6
*7 Set each digit using the individual U (D) Keys.
Twin Counter
will not be displayed.
When using as a batch counter
When using as a 2-stage preset counter
g-o
(Three digits after
decimal point)
(L)
l
*6
o-g
(H)
h
*6
Output 2
output
time
(OTM2)
Output 1
output
time
(OTM1)
One-shot
output 2
time
(OTM2)
One-shot
output 1
time
(OTM1)
One-shot
output 2
time
(OTM2)
*3 When Using Dual Counter
• Set the dual count calculating
*4 Displayed only when the output mode is K-2,
Operation
mode using the UD Keys.
D, L, or H.
Note: Displayed only when the
(Addition) (Subtraction)
Note: Displayed only when the
Note: Displayed only when the
Note: Displayed only when the
Note: Displayed for output modes
If the output time is 0.00, hold is displayed.
add
(Outputs held)
(0.01 s)
(0.01 s)
(0.01 s)
(0.01 s)
0.01
0.01
output mode is C, R, K-1, P, Q,
A, or K-2.
0.01
output mode is C, R, K-1, P, Q,
A, or K-2.
0.01
output mode is C, R, K-1, P,
Q, or A.
hold
output mode is C, R, K-1, P,
Q, or A.
other than D, L, and H.
HOLD cannot be set when
the output mode is K-2.
(0.50 s) (99.99 s)
(0.50 s) (99.99 s)
(0.50 s) (99.99 s)
(0.50 s) (99.99 s)
0.50
0.50
sub
(0.01 s) (99.99 s)
0.50
0.01 99.99
0.50
*4
Dual count
calculating
mode
(ADD)
99.99
99.99
99.99
99.99