H12WD4850 Crydom Company, H12WD4850 Datasheet - Page 3

no-image

H12WD4850

Manufacturer Part Number
H12WD4850
Description
Relay; SSR; Zero-Switching; Cur-Rtg 50A; Ctrl-V 4-32DC; Vol-Rtg 48-660AC; Pnl-Mnt
Manufacturer
Crydom Company
Datasheet

Specifications of H12WD4850

Brand/series
H12WD Series
Current, Leakage, Off-state
1 mA (RMS)
Current, Rating
50 A
Current, Surge
625 Apeak
Dielectric Strength
4000 V (RMS)
Dimensions
2.30 in. L x 1.80 in. W x 0.90 in. H
Function
Zero-Switching
Mounting Type
Panel
Number Of Pins
4
Relay Type
Solid State
Resistance, Thermal, Junction To Case
0.63 °C⁄W
Standards
UL, CSA, VDE, CE
Temperature, Ambient, Maximum
80 °C
Temperature, Ambient, Minimum
-40 °C
Termination
Saddle Clamp
Transient Overvoltage
1200 Vpeak
Voltage, Control
32 VDC
Voltage, Rating
660 VAC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H12WD4850
Manufacturer:
Crydom Co.
Quantity:
135
OUTPUT SPECIFICATIONS 1
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
Min. Load Current, [mArms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R θ JC ) [°C/W]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2 sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS 1
Control Voltage Range
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
GENERAL NOTES
1
2
3
4
5
6
SERIES H12WD.
Rev. 052307
PAGE 1 OF 3
All parameters at 25°C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
Turn-on time for DC control random turn-on versions is 0.02 msec.
Input circuitry incorporates active current limiter.
Compliant only.
3
4
[Arms]
M O D E L N U M B E R S
2
• 1200 Volt Blocking
• Panel Mount
• Up to 660 Vac
• Zero Voltage and Random
• SCR Output
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
Turn-On
H12WD4825
1/2 Cycle
1/2 Cycle
1200
48-660
1.02
150
250
260
1.6
500
1.0
0.5
25
H12WD4850
1/2 Cycle
1/2 Cycle
1200
1620
48-660
150
625
1.6
500
1.0
0.5
.63
50
15 mA @ 5 Vdc
4-32 Vdc
See Note 5
© 2007 CRYDOM Inc., Specifications subject to change without notice.
4.0 Vdc
1.0 Vdc
H12WD4875
Series
25-125Amp • 480 Vac - AC OUTPUT
48-660
1/2 Cycle
1/2 Cycle
High voltage relays use IC driven cir-
cuits for switching loads up to 660
VAC. All models come with 1200
Volts blocking.
Type H12WD is a snubberless
(reduced leakage current).
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
1200
1000
150
4150
500
75
1.6
.31
1.0
0.5
5
H12WD4890
1/2 Cycle
1/2 Cycle
48-660
H12WD
1200
1200
150
6000
500
90
1.6
.28
1.0
0.5
H12WD48125
1/2 Cycle
1/2 Cycle
48-660
1750
1200
12700
150
125
500
1.7
.22
1.0
0.5
6

Related parts for H12WD4850