BE750G American Power Conversion (APC), BE750G Datasheet - Page 7

no-image

BE750G

Manufacturer Part Number
BE750G
Description
Back-UPS, ES 10 Outlet, 750VA, 120V, Master Control
Manufacturer
American Power Conversion (APC)
Type
Home/Office, Networkr
Datasheet

Specifications of BE750G

Brand/series
Back-UPS®
Capacity
750 VA
Color
Black
Communication
RJ45, USB
Dimensions
88mmH×180mmW×343mmD
Input Type
NEMA 5-15P
Length, Cord
1.83 m
Operation
Online
Output Type
(5) NEMA 5-15R
Power, Rating
450 W
Time, Backup
2.5 min.
Voltage, Output
120 V
Voltage, Supply
450/750 W/VA
Weight
4.7 kg
Specifications
Internet connection lost during power outage.
Input
Output
Protection and Filter AC Surge Protection
Battery
Physical
Safety/Regulatory
990-3153A 9/07
Back-UPS ES will not turn on.
No power available at the Surge Protection
outlets.
Back-UPS turns on, but LED flashes and unit
emits a constant tone.
Connected equipment loses power.
The Power On indicator is lit and the Back-
UPS ES is beeping four times every 30
seconds.
The Power On indicator flashes and beeps
twice per second at the same time.
Building Wiring Fault indicator is lit.
Inadequate runtime.
No phone/fax/DSL/cable or network signal
from the Back-UPS.
Troubleshooting
Model
Problem
Voltage
Frequency
Brownout Transfer
Over-voltage Transfer
UPS Capacity (5 outlets)
Total Amperage (10 outlets)
Voltage
On Battery
Frequency - On Battery
Transfer Time
Phone/Fax/DSL Surge
Protection
Cable/CATV/DSS Surge
Protection
Network Surge Protection
EMI/RFI Filter
AC Input
Model
Type
Average Life
Net Weight
Size
Operating Temperature
Storage Temperature
Operating Relative Humidity
Operating Elevation
Safety Approvals
EMC Compliance
Use the table below to solve minor Back-UPS ES installation or operation problems. Consult APC Online Technical Support or call APC
Technical Support for assistance with problems that cannot be resolved using the table below:
Modem lost AC power.
The battery is disconnected, and either power is
unavailable at the wall outlet, or utility power is having a
“brownout” or an “over voltage” condition.
Surge Protection outlets have been overloaded.
Utility power not available at the wall outlet.
Battery is disconnected.
Equipment is connected to the “Surge Protection” outlets.
The Back-UPS ES is overloaded.
PowerChute Personal Edition software has performed a
shutdown due to a power failure.
The Back-UPS ES has exhausted its available battery
power.
Connected equipment does not accept the step-
approximated sine waveform the Back-UPS ES.
The Back-UPS ES may require service.
The Back-UPS ES is using battery.
Battery capacity is low (about 2 minutes of use remaining).
Your building wiring presents a shock hazard. Using the
Back-UPS with this condition will void the warranty.
The battery is not fully charged.
Battery is near the end of useful life.
Data line from the ISP or wall outlet is connected to the
wrong jack on the Back-UPS.
Probable Cause
TUV C-US certified per UL Std. 1778 and CSA 22.2
No. 107.1, NOM-001
Notice: This device complies with part 68 and
part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) This device may
not cause harmful interference, and (2) This
device must accept any interference received,
including interference that may cause undesired
operation.
On the bottom of this equipment is a label that
contains, among other information, the FCC
registration number and ringer equivalence
number (REN) for this equipment.
If requested, this information must be provided
to the telephone company.
3 - 5 years depending on the number of discharge
cycles and environmental temperature
Sealed, maintenance-free lead acid
12 Amps (including UPS output)
(step-approximated sine wave)
+5
+32
6 ms typical, 10 ms maximum
3.5" (H) x 13.5" (W) x 7.1" (D)
0 to 10,000 ft (0 to 3,000m)
(88.3 x 342.7 x 180.0 mm)
50 - 60 Hz (auto-sensing)
Resettable circuit breaker
o
0 to 95% non-condensing
One Coax Input/Output
10/100Base-T Ethernet
F to 113
o
Full time, 354 joules
F to 104
120 Vrms Nominal
Single line (2-wire)
10.36 lb. (4.70 kg.)
142 Vrms, typical
50-60 Hz + 1 Hz
88 Vrms, typical
750 VA / 450 W
115 Vrms + 8%
BE750G
Full time
RBC17
o
F (-15
o
F (0
o
o
C to 40
C to 45
o
o
C)
C)
Order Replacement Battery
Service
Warranty
The standard warranty is 3 years from the date of purchase. APC’s standard procedure
is to replace the original unit with a factory reconditioned unit. Customers who must
have the original unit back due to assigned asset tags and set depreciation schedules
must declare such a need at first contact with APC Technical Support. APC will ship the
replacement unit once the defective unit is received by the repair department or cross-
ship upon the provision of a valid credit card number. The customer pays for shipping
to APC, and APC pays ground freight transportation costs back to the customer.
Replace with an APC qualified battery. Replacement batteries can be ordered from
www.apc.com (valid credit card required). Have your Back-UPS ES model number
available when ordering. Your model number can be found on the bottom of the unit.
Plug the modem’s AC power cord into one of the “Battery Back-up plus Surge
Protection” outlets.
Connect the battery (see Connect Battery) and ensure power is available at the wall
outlet. If battery is connected and power is unavailable, the unit can be “cold started”
(operated on battery power) by holding the power button down until two beeps are
heard.
Reduce the amount of equipment plugged into Surge Protection outlets.
Ensure the fuse or circuit breaker for the outlet is not tripped, and that the wall switch
controlling the outlet (if any) is in the ON position.
Connect the battery (see Connect Battery diagram).
Ensure the equipment you want to stay powered during a power failure is plugged
into the “Battery Backup plus Surge Protection” outlets and NOT the “Surge
Protection” outlets.
Make sure the equipment plugged into the outlets of the unit are not overloading its
capacity. Try removing some of the equipment and see if the problem continues.
The Back-UPS ES is operating normally.
The Back-UPS ES can only operate on battery power for a limited amount of time.
The unit will eventually turn off when the available battery power has been used.
Allow the unit to recharge for 16 hours before expecting maximum runtime.
The output waveform is designed for computers and computer-related equipment. It
is not designed for use with motor-type equipment.
Contact APC Technical Support for further troubleshooting.
The Back-UPS ES is operating normally and using battery power. Once On Battery,
you should save your current work, power down your equipment, and turn the unit
OFF. Once normal power is restored, you may turn the unit back ON and power your
equipment.
The Back-UPS ES is about to shut off due to a low battery charge condition! When
the unit beeps twice every second, the battery has about 2 minutes of power
remaining. Immediately power down your computer and turn the unit OFF. When
normal power returns, the unit will recharge the battery.
Call a qualified electrician for service.
Allow the unit to charge by leaving it plugged into the wall for at least 16 hours.
As a battery ages, the amount of runtime available will decrease. You can replace the
battery by ordering one at www.apc.com. Batteries also age prematurely if the Back-
UPS ES is placed near excessive heat.
Make sure the data line from the wall outlet is connected to the jack labeled “Wall
Outlet (Phone/Fax/DSL), or “Cable In” (Cable/DSS/CATV).
Please DO NOT RETURN Back-UPS ES to the place of purchase under any
circumstances.
1. Consult the Troubleshooting section to eliminate common problems.
2. Verify the battery is connected (see Connect Battery) and that the Circuit Breaker is
not tripped (see Troubleshooting section).
If you still have problems or questions, please contact APC via the internet or at one of
the phone numbers listed below.
3. Before contacting APC, please be sure to record the date purchased, UPS model,
and serial number (on bottom of unit).
4. Be prepared to troubleshoot the problem over the telephone with a Technical
Support Representative. If this is not successful, the representative will issue a Return
Material Authorization Number (RMA#) and a shipping address.
5. Pack the unit in its original packaging. If the original packaging is not available, ask
APC Technical Support about obtaining a new set. Pack the unit properly to avoid
damage in transit. Never use foam beads for packaging. Damage sustained in transit is
not covered under warranty (insuring the package for full value is recommended).
6. Write the RMA# on the outside of the package.
7. Return the unit by insured carrier to the address given to you by APC Technical
Support.
Solution