H3CR-A-AC24-48/DC12-48 Omron Automation, H3CR-A-AC24-48/DC12-48 Datasheet - Page 10

no-image

H3CR-A-AC24-48/DC12-48

Manufacturer Part Number
H3CR-A-AC24-48/DC12-48
Description
Relay; SSR; Timing; On Delay; DPDT; Cur-Rtg 5, 0.15A; Ctrl-V 24-48/12-48AC/DC; 11 Pin
Manufacturer
Omron Automation
Datasheet

Specifications of H3CR-A-AC24-48/DC12-48

Contact Form
DPDT
Current, Rating
5, 0.15 A
Function
Timing
Mounting Type
DIN Rail⁄SMD
Number Of Pins
11
Relay Type
Solid State
Standards
UL, CSA, CE
Temperature, Operating, Maximum
55 °C
Temperature, Operating, Minimum
-10 °C
Timer Type
On Delay
Timing Range
0.05 sec. to 300 hrs.
Voltage, Control
48 VAC⁄VDC
Voltage, Rating
250⁄125 VAC⁄VDC
Timing Functions
4 Function
6 Function
ON-Delay, Repeat Cycle ON or OFF, Signal ON/OFF, Signal OFF, Interval (11-Pin)
Timing Ranges
Multi-Function
Lead Free Status / Rohs Status
RoHS Compliant part
H3CR-AP
Voltage Inputs
The start input of the H3CR-AP is voltage input. (Voltage imposition or open)
Note: Before making connections, refer to Safety Precautions (H3CR-
No-contact Input
(Connection to PNP open
collector output sensor)
Sensor
Voltage Input Signal Levels
12 to 24 VDC
(sensor power supply)
No-contact
input
Contact
input
Operates with PNP transistor ON
Use contacts that can adequately switch 0.1 mA at each
operating voltage.
The voltage between terminals 6 and 7 with contacts ON or
OFF must satisfy the specified value.
Contacts ON
100-to-240-VAC and 100-to-125-VDC models: 85 to 264 VAC
or 85 to 137.5 VDC
24-to-48-VAC and 12-to-48-VDC models: 20.4 to 52.8 VAC or
10.8 to 52.8 VDC
Contacts OFF
100-to-240-VAC and 100-to-125-VDC models: 0 to 10 VAC or
0 to 10 VDC
24-to-48-VAC and 12-to-48-VDC models: 0 to 2.4 VAC or 0 to
1.2 VDC
1. Transistor ON
Residual voltage: 1 V max.
The voltage between terminals 6 and 7 must be 10.8 VDC min.
2. Transistor OFF
Leakage current: 0.01 mA max.
The voltage between terminals 6 and 7 must be 1.2 VDC max.
+
2
10
6
7
Timer
DC power
supply
Power
supply (+)
Start
Input 0V
Power
supply
(−)
Note: The input circuit is isolated from the
No-contact Input
(Connection to NPN open
collector output sensor)
Sensor
power supply circuit. Thus, an NPN
transistor can be connected.
12 to 24 VDC
(sensor power supply)
Operates with NPN transistor ON
@
+
).
10
6
7
2
DC power
supply
Timer
Power
supply (+)
Start
Input 0V
Power
supply (−)
Note: Refer to the signal levels in the
Contact Input
Operates with relay ON
following table and be aware of the
minimum applicable load of the relay.
10
6
7
2
Timer
Power
supply (+)
Start
Input 0V
Power
supply (−)
H3CR-A
10