H3CR-F8 AC100-240 Omron Automation, H3CR-F8 AC100-240 Datasheet - Page 7

no-image

H3CR-F8 AC100-240

Manufacturer Part Number
H3CR-F8 AC100-240
Description
Timer; Repeat Cycle; 0.05s-30h; E-Mech; Ctrl-V 100-240AC; 5A@250VAC/30VDC; 8-Pin Octal
Manufacturer
Omron Automation
Datasheet

Specifications of H3CR-F8 AC100-240

Current, Rating
5 A
Function
Timing
Mounting Type
Socket
Number Of Pins
8
Relay Type
Electro Mechanical
Repeatability
±0.3% (Max.)
Standards
UL, CSA, CE
Temperature, Operating, Maximum
+55 °C
Temperature, Operating, Minimum
-10 °C
Termination
Plug-In
Timer Type
Repeat Cycle
Timing Range
0.05s-30h
Voltage, Control
100-240 VAC
Voltage, Rating
250 VAC⁄30 VDC VAC⁄VDC
Timing Functions
4 Function
6 Function
ON-Delay, Repeat Cycle ON or OFF, Signal ON/OFF, Signal OFF, Interval (11-Pin)
Timing Ranges
Multi-Function
Lead Free Status / Rohs Status
RoHS Compliant part
Operation (Common)
Note: The undermentioned is common for all H3CR models.
■ Basic Setting
Setting of Selectors
The selectors can be turned clockwise and counterclockwise to
select the desired time unit, time range, or operating mode.
Each selector has a snap mechanism that secures the selector at a
given position. Set the selector at a position at which it is secured. Do
not set it midway between two securing positions or a malfunction
could result from improper setting.
Selection of Operating Mode
• H3CR-A Multifunctional Timer
Turn the operating mode selector with a screwdriver until the desired
operating mode (H3CR-A/AP/AS: A, B, B2, C, D, or E, H3CR-A8/
A8S/A8E: A, B2, E or J, H3CR-A-300: G or J) appears in the display
window located above the selector.
Selection of Time Unit and Time Range
• H3CR-A Multifunctional Timer
The desired time unit (sec, min, hrs, or 10h) is displayed in the
window below the time setting knob by turning the time unit selector
located at the lower right corner of the front panel. A time range (1.2,
3, 12, or 30/2.4, 6, 24, or 60 for H3CR-A@-301) is selected with the
time range selector at the lower left corner of the front panel, and the
selected time range appears (in the window at the lower right part)
within the plastic frame of the time setting knob.
Operating mode
selector
Time setting
knob
Time range
selector
(i.e., H3CR-A)
Time unit display window
Time unit selector
Operating mode
display window
Scale range
display window
Groove for
screwdriver
• H3CR-F Twin Timers
A time range (0 to 1.2, 0 to 3, 0 to 12, or 0 to 30) is selected for ON-
and OFF-time using the time range selector at the lower left corner of
the front panel, and the selected time range appears within the
plastic frame of the time setting knob (= scale range display
windows).
For ON-time, the desired time unit (sec, 10 s, min, and hrs, or 10 s,
10 min, hrs, and 10 h) is indicated in the ON-time unit display window
at the lower right corner of the front panel and can be changed by
turning the ON-time unit selector located below the ON-time unit
display window.
For OFF-time, the desired time unit (sec, 10 s, min, and hrs, or 10 s,
10 min, hrs, and 10 h) is indicated in the OFF-time unit display
window at the upper right corner of the front panel and can be
changed by turning the OFF-time unit selector located below the
OFF-time unit display window.
Time range
selector
CSM_H3CR-Common_DS_E_1_1
ON-time unit
selector
OFF-time unit
selector