E5CN-R2MT-500AC100240 Omron Automation, E5CN-R2MT-500AC100240 Datasheet - Page 9

no-image

E5CN-R2MT-500AC100240

Manufacturer Part Number
E5CN-R2MT-500AC100240
Description
Controller, Digital Temp, 48x48mm, Relay Out, Thermoc In, 100-240VAC, 2Aux Out
Manufacturer
Omron Automation
Type
Temperaturer
Datasheet

Specifications of E5CN-R2MT-500AC100240

Brand/series
E5CN Series
Communication
USB
Contact Form
SPST-NO
Dimensions
48mmW×48mmH×78mmD
Enclosure Rating
IP00, IP20, IP66
Input Type
RTD/Thermocouple
Ip Rating
IP00, IP20, IP66
Mounting Type
DIN Rail
Number Of Outputs
3
Output Type
Relay
Primary Type
Controller
Special Features
USB Serial
Standards
UL, cULus, CSA
Termination
Terminal Block
Voltage, Supply
100 to 240 VAC
Supply Voltage
100-240 VAC or 24 VAC/VDC
Current Output
4-20 mA DC (E5CN-E5AN-E5EN)
Thermocouple Inputs
K, J, T, L, E, U, N, R, S, B
Platinum Rtd
Pt100 and JPt100
Infrared Sensor
10-70°C, 60-120°C, 115-165°C, 160-260°C
Voltage
0 to 50 mV
Lead Free Status / Rohs Status
RoHS Compliant part
Characteristics
✽1. The indication accuracy of K thermocouples in the −200 to 1300°C range, T and N thermocouples at a temperature of −100°C max., and U and L
✽2. Ambient temperature: −10°C to 23°C to 55°C, Voltage range: −15% to 10% of rated voltage
✽3. K thermocouple at −100°C max.: ±10° max.
✽4. “EU” stands for Engineering Unit and is used as the unit after scaling. For a temperature sensor, the EU is °C or °F.
✽5. When robust tuning (RT) is ON, the differential time is 0.0 to 999.9 (in units of 0.1 s).
✽6. External communications (RS-485) and cable communications for the Setup Tool can be used at the same time.
✽7. The E5CN-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket.
Indication accuracy
Influence of temperature ✽2
Influence of voltage ✽2
Input sampling period
Hysteresis
Proportional band (P)
Integral time (I)
Derivative time (D)
Control period
Manual reset value
Alarm setting range
Affect of signal source resis-
tance
Insulation resistance
Dielectric strength
Vibration
resistance
Shock
resistance
Weight
Degree of
protection
Memory protection
Setup Tool
Setup Tool port
Standards
EMC
thermocouples at any temperatures is ±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max. is not specified.
The indication accuracy of B thermocouples in the 400 to 800°C range is ±3°C max. The indication accuracy of the R and S thermocouples at a temperature
of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is ±0.3 of PV or ±3°C, whichever is greater, ±1 digit max. The indication
accuracy of PL II thermocouples is ±0.3 of PV or ±2°C, whichever is greater, ±1 digit max.
The P3GA-11 is not certified for UL listing.
Malfunction
Destruction
Malfunction
Destruction
E5CN
E5CN-U
E5CN
E5CN-U
Approved
standards ✽7
Conformed
standards
Thermocouple: ✽1
Platinum resistance thermometer input:
±1 digit max.
Analog input:
CT input:
Thermocouple input (R, S, B, W, PL II):
Other thermocouple input: ✽3
Platinum resistance thermometer input:
Analog input:
250 ms
Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1 EU) ✽4
Models with analog input: 0.01 to 99.99% FS (in units of 0.01% FS)
Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1 EU) ✽4
Models with analog input: 0.1 to 999.9% FS (in units of 0.1% FS)
0 to 3999 s (in units of 1 s)
0 to 3999 s (in units of 1 s) ✽5
0.5, 1 to 99 s (in units of 1 s)
0.0 to 100.0% (in units of 0.1%)
−1999 to 9999 (decimal point position depends on input type)
Thermocouple: 0.1°C/Ω max. (100 Ω max.)
Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)
20 MΩ min. (at 500 VDC)
2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)
10 to 55 Hz, 20 m/s
10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions
100 m/s
300 m/s
Controller: Approx. 150 g, Mounting Bracket: Approx. 10 g
Controller: Approx. 110 g, Mounting Bracket: Approx. 10 g
Front panel: IP66, Rear case: IP20, Terminals: IP00
Front panel: IP50, Rear case: IP20, Terminals: IP00
Non-volatile memory (number of writes: 1,000,000 times)
CX-Thermo version 4.0 or higher
Provided on the bottom of the E5CN. Use this port to connect a computer to the E5CN when using the Setup Tool. An
E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5CN. ✽6
UL 61010-1, CSA C22.2 No. 1010-1
EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II
EMI:
Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A
Noise Terminal Voltage:
EMS:
ESD Immunity:
Electromagnetic Field Immunity:
Burst Noise Immunity:
Conducted Disturbance Immunity:
Surge Immunity:
Power Frequency Magnetic Field Immunity:
Voltage Dip/Interrupting Immunity:
Terminal block models (E5CN): (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max.
Plug-in models (E5CN-U): (±1% of indicated value or ±2°C, whichever is greater) ±1 digit max.
Terminal block models (E5CN) and plug-in models (E5CN-U): (±0.2% of indicated value or ±0.8°C, whichever is greater)
Terminal block models (E5CN) and plug-in models (E5CN-U): ±0.2% FS ±1 digit max.
Terminal block models (E5CN): ±5% FS ±1 digit max.
Terminal block models (E5CN): (±1% of PV or ±10°C, whichever is greater) ±1 digit max.
Plug-in models (E5CN-U): (±2% of PV or ±10°C, whichever is greater) ±1 digit max.
Terminal block models (E5CN): (±1% of PV or ±4°C, whichever is greater) ±1 digit max.
Plug-in models (E5CN-U): (±2% of PV or ±4°C, whichever is greater) ±1 digit max.
Terminal block models (E5CN) and plug-in models (E5CN-U):
(±1% of PV or ±2°C, whichever is greater) ±1 digit max.
Terminal block models (E5CN) and plug-in models (E5CN-U): (±1%FS) ±1 digit max.
2
2
, 3 times each in X, Y, and Z directions
, 3 times each in X, Y, and Z directions
2
for 10 min each in X, Y, and Z directions
EN 61326
EN 55011 Group 1, class A
EN 61326
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
EN 61000-4-5
EN 61000-4-8
EN 61000-4-11
E5CN/E5CN-U
11

Related parts for E5CN-R2MT-500AC100240