MIC2012CM Micrel Inc, MIC2012CM Datasheet - Page 3

IC USB PWR CTRLR DUAL 8-SOIC

MIC2012CM

Manufacturer Part Number
MIC2012CM
Description
IC USB PWR CTRLR DUAL 8-SOIC
Manufacturer
Micrel Inc
Datasheet

Specifications of MIC2012CM

Controller Type
USB Power Controller
Interface
USB
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
1mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Input Voltage
5V
On State Resistance
0.1ohm
Thermal Protection
Yes
No. Of Outputs
2
Internal Switch
Yes
Distribution Switch Case Style
SOIC
No. Of Pins
8
Current Limit
1.8A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MIC2012CM
Manufacturer:
MICREL
Quantity:
63
Part Number:
MIC2012CM
Manufacturer:
MICREL/麦瑞
Quantity:
20 000
Company:
Part Number:
MIC2012CM
Quantity:
1 038
Part Number:
MIC2012CMTR
Manufacturer:
MIC
Quantity:
20 000
Pin Description
January 2005
MIC2012
Pin Number
(MIC2012)
n/a
n/a
n/a
1
2
3
4
5
6
7
8
(MIC2012-1, -2)
Pin Number
4, 6, 7
13, 14
11, 12
9, 10
15
16
1
2
3
5
8
Pin Name
FAULT1
FAULT2
OUT2
OUT1
MAIN
GND
EN1
AUX
EN2
S3#
NC
Pin Function
Fault Status (Output): Internal pull-up or open-drain. Asserted LOW when
Channel is in a thermal shutdown state or overcurrent condition for more
than 5ms. MIC2072 latches this output in its asserted state upon an over-
current condition. Toggling EN1 or removing the load will reset the circuit
breaker latch and deassert FAULT1.
Enable (Input): Channel 1, active-high (–1) or active-low (–2). Toggling this
input also resets the latched output of the MIC2072.
Control (Input): When this input is HIGH, the MAIN inputs are connected to
OUT1 and OUT2 via 100mΩ MOSFET switches. When this input is LOW
the AUX inputs are connected to OUT1 and OUT2 via 500mΩ MOSFET
switches.
Auxiliary 5V Supply (Input): Also used as power supply for internal circuitry.
No Connection: This pin may be connected to other pins without restriction.
Ground
Channel 2 (Output): For MIC2012-1, -2 both pins must be externally con-
nected together.
5V Main Supply (Input): All MAIN inputs must be connected together exter-
nally.
Channel 1 (Output): For MIC2012-1, -2 both pins must be externally con-
nected together.
Enable (Input): Channel 2, active-high (–1) or active-low (–2). Toggling this
input also resets the latched output of the MIC2072.
Fault Status (Output): Internal pull-up or open-drain. Asserted LOW when
Channel 2 is in a thermal shutdown state or overcurrent condition for more
than 5ms. MIC2072 latches this output in its asserted state upon an over-
current condition. Toggling EN2 or removing the load will reset the circuit
breaker latch and deassert FAULT2.
3
MIC2012/2072
Micrel

Related parts for MIC2012CM