SFL6-12-100 SOLA HEVI DUTY, SFL6-12-100 Datasheet - Page 2

no-image

SFL6-12-100

Manufacturer Part Number
SFL6-12-100
Description
Linear & Switching Power Supplies 75W 12VDC @ 6A
Manufacturer
SOLA HEVI DUTY
Datasheet

Specifications of SFL6-12-100

Product
Switching
Output Power Rating
72 W
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
6 A
Dimensions
90 mm L x 56.7 mm W x 114.6 mm H
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SFL Specifications
Mounting Brackets
For easy conversion to panel or chassis mounting.
Input voltages nominal (user selectable)
Input Frequency
Input current at full load (typical)
Inrush current (max.)
Internal fuse (slow blow) not accessible
Voltage Adjustment Range
Output Regulation
Ripple and noise (20 MHz bandwidth)
Electronic short circuit protection /
current limitation
Parallel Operation
Overvoltage Protection, trigger point at
Holdup Time
- 75 W (12 V/6 A, 24 V/3 A, 48 V/1.5 A)
- 150 W (24 V/6 A, 48 V/3 A)
- 300 W (24 V/12 A, 48 V/6 A)
- 600 W (24 V/24 A, 48 V/12 A)
- 75 W
- 150 W
- 300 W
- 600 W
- 75 W / 150 W
- 300 W
- 600 W
- 12 V models
- 24 V models
- 48 V models
- Line voltage variation
- Load variation 10–90%
- SFL12-24-100RED
- SFL24-24-100RED
75W, 150W models
300W, 600W models
SFL 150-PMBRK
SFL 300-PMBRK
SFL 600-PMBRK
Catalog Number
SFL 75-PMBRK
Parameter
Output
Input
110 % typ. (constant current)
contact Technical Services at (800) 377-4384 with any questions.
93-132 Vac / 187-264 Vac
115 Vac
115 Vac
140% typical out nominal
16.5 A
35.0 A
35.0 A
70.0 A
Output Power Maximum
10.5A
1.7A
3.0A
5.4A
Up to 5 units
12 – 14 Vdc
24 – 28 Vdc
48 – 52 Vdc
±0.2% max.
±1.0% max.
±0.5% max.
min. 20 mS
< 50 mVpp
150 Watt
300 Watt
600 Watt
75 Watt
47-63 Hz
12.0 A
4.0 A
6.3 A
Value
Visit our website at www.solahd.com or
230 Vac
230 Vac
33.0 A
70.0 A
70.0 A
80.0 A
0.9 A
1.7 A
3.3 A
6.4 A
Power Supplies
Operating Temperature Range
Derating above 50°C
Storage Temperature
Humidity (non condensing)
Switching Frequency
Efficiency
Operation Indication
Isolation Voltage
Safety Class (IEC536)
Safety Standards Met
Conducted EMI according to:
Electromagnetic Susceptibility
Case protection according to IEC529
Case material
Mounting
- 75 W
- 150 W/300 W/600 W
- Input/output
- Input/case
- Output/case
- Electrostatic discharge ESD.
- RF field susceptibility.
- Electrical fast transients/
- Immunity to conducted radio
- Mains frequency field
bursts on main line.
frequency disturbances above
9 kHz.
Parameter
General
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-8
per EN50022 or Chassis mounting
IEC950,EN60950,CE marked
for LVD, UL60950 recognized
EN55022 Class B, EN55011
Snap-on 35 mm DIN Rail as
-25°C...+70°C 2%/°C
3,000 Vac (1 minute)
2,000 Vac (1 minute)
500 Vac (1 minute)
Class B, FCC-B
95% rel H max.
100 kHz typical
option available
67 kHz typical
-25°C...+85°C
LED, DC OK
and UL 508.
Class 1
>85%
Value
IP 20
Steel
4 kV/8 kV
10 V/m
30 A/m
2 kV
10 V
4
135