SDN4-24-100 SOLA HEVI DUTY, SDN4-24-100 Datasheet - Page 4

no-image

SDN4-24-100

Manufacturer Part Number
SDN4-24-100
Description
Linear & Switching Power Supplies USE 663-SDN4-24-100P
Manufacturer
SOLA HEVI DUTY
Datasheet

Specifications of SDN4-24-100

Product
Switching
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SDN
Effi ciency (Losses)
Power Factor Correction
MTBF
General Protection/
Safety
(inches/mm)
Approvals
Nominal Voltage
Nominal Current
Nominal Voltage
Nominal Current
Holdup Time
Parallel Operation
EMC
Temperature
-Standard
Warranty
Status Indicators
Fusing
Mounting
Connections
Case
H x W x D
Weight (lbs/g)
1
2
3
4
5
- Emissions
-AC Range
-DC Range
-Frequency
-Inrush current max.
-Tolerance
-Ripple
-Peak Current
-Current Limit
-Immunity
-Input
-Output
-Free Space
Description
For the SDN 20-24-480C, single phase input is permissable, but output is derated to 75% (15 Amps @ 24 VDC).
Input current ratings are conservatively specifi ed with low input, worst case effi ciency and power factor.
Losses are heat dissipation in watts at full load, nominal input line.
Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
For the SDN 40-24-480, output: one (+) two (-) connectors, size range 16-5 AWG (1.5016 mm
TM
4
Specifi cations (Three Phase)
3
Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for fl exible conductors. Output: Two connec-
6 A 2x Nominal Current <2sec.
Storage: -25oC...+85oC Operation. -10oC -60oC full power with operation to 70oC possible with a linear derating to half power from 60oC to 70oC (Convection cooling, no
(124 mm x 73 mm x 116 mm)
Protected against continuous short-circuit, overload, open-circuit. Protection class 1 (IEC536), degree of protection IP20 (IEC 529) Safe low voltage: SELV (acc.EN60950)
forced air required). Operation up to 50% load permissable with sideways or front side up mounting orientation. The relative humidity is < 90% RH, noncondensing; IEC
4.88 in. x 2.91 in. x 4.55 in.
25 mm above and below, 25 mm left and right, 15 mm in front
EN61000-6-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation Class 4,
CB Scheme, EN60950; EN50178; EN60204; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC). EN61000-3-2, IEC 60079-15 (Class 1, Zone 2
> 1,110,000 hours
> 90% typ (12 W)
SDN 5-24-480
1.7 lbs (730g)
5 A (120 W)
Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping.
5A through 30A units may be passively paralleled by selecting the “P” position of the switch on the unit. The SDN40 contains active current balancing.
0.5 A
Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required).
1Ø or 3Ø 380-480 VAC
Contact Technical Services at (800) 377-4384 with any ques tions.
> 40 ms
Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current)
Outputs are capable of providing high currents for short periods of time for inductive load startup or switching.
12 A 2x Nominal Current <2 sec.
(124 mm x 89 mm x 116 mm)
4.88 in. x 3.5 in. x 4.55 in.
EN61000-6-3, -4; Class B EN55011, EN55022 Radiated and Conducted including Annex A.
Visit our website at www.solaheviduty.com or
SDN 10-24-480
> 940,000 hours
EN61000-4-11; Transient resistance according to VDE 0160/W2 over entire load range.
2.16 lbs (980g)
10 A (240 W)
tors per output, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors.
typ. < 18 A
< ±2% overall (combination Line, load, time and temperature related changes)
Fully enclosed metal housing with fi ne ventilation grid to keep out small parts.
hazardous location, Groups IIA, IIB, IIC w/T3 temp class up to 60°C Ambient.
0.8 A
> 90% typ (48 W)
Power Supplies
Green LED on when Vout = 18V or greater.
2)
solid conductor.
Installation
General
Output
25 A 2x Nominal Current <2sec.
Input
(124 mm x 150 mm x 116 mm)
24 VDC (22.5 - 28.5 VDC adj.)
1Ø or 3Ø 380 - 480 VAC
4.88 in. x 5.9 in. x 4.55 in.
Units Fulfi ll EN61000-3-2
SDN 20-24-480C
Catalog Number
> 550,000 hours
3.97 lbs (1800g)
MIL217F @ 30C
Internally fused.
450 - 820 VDC
68-2-2, 68-2-3.
340 - 576 VAC
20 A (480 W)
< 50 mVpp
47 - 63 Hz
> 28 ms
5 years
1.5 A
70 mm above and below, 25 mm left and right , 15 mm in front
1
35 A 2x Nominal Current < 2 sec.
(124 mm x 247 mm x 116 mm)
4.88 in. x 9.72 in. x 4.55 in.
SDN 30-24-480
> 90% typ (72 W)
> 620,000 hours
4 lbs (2000g)
30 A (720 W)
2.0 A
5
3Ø 380 - 480 VAC
typ. < 30 A
> 20 ms
45 A 2x Nominal Current<2 sec
(124 mm x 282 mmx 116 mm)
4.88 in. x 11.1 in. x 4.55 in.
SDN 40-24-480
> 90% typ (96 W)
> 490,000 hours
6.6 lbs (3300g)
40 A (960 W)
3.0 A
89

Related parts for SDN4-24-100