GLD140G SL Power, GLD140G Datasheet

Linear & Switching Power Supplies 140W 4 Output +5V/+3.3V/12V/-12V

GLD140G

Manufacturer Part Number
GLD140G
Description
Linear & Switching Power Supplies 140W 4 Output +5V/+3.3V/12V/-12V
Manufacturer
SL Power
Series
GLDr
Datasheet

Specifications of GLD140G

Product
Switching
Commercial/medical
Medical
Output Power Rating
80 W
Input Voltage
90 VAC to 264 VAC
Number Of Outputs
4
Output Voltage (channel 1)
5 V
Output Current (channel 1)
16 A
Output Voltage (channel 2)
+ 3.3 V
Output Current (channel 2)
10 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
4 A
Mounting Style
Chassis
Dimensions
215.9 mm L x 114.3 mm W x 49.53 mm H
Open Frame/enclosed
Open Frame
Output Type
Multiple Output
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
DC POWER SUPPLIES INC.
2311 Statham Pkwy
Oxnard, CA 93033 + 805-486-4565
www.condorpower.com
MODEL NUMBERS: GLD140X-C or -CF where X equals any alpha character A through Z, -C is a slotted cover option
and –CF is a solid cover with fan option. Models may be followed by suffix –XXX and/or G, where XXX may be any
number from 001 thru 999. The –XXX suffix are used for value added configurations that have no impact on safety and
suffix G indicates compliance to RoHS.
RATINGS:
Input: 100-240 V ac, 3.0 A, 50/60 Hz
Output:
Notes:
1.
2.
3.
4.
CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of UL 60601-1, CSA
22.2 No. 601.1, EN 60601-1, and IEC 60601-1.
CLASSIFICATION
GROUNDING: Protection Class I requires that the ground terminal be bonded to Protective Earth in the end application.
Using this terminal for the primary system earthing terminal is not recommended.
OUTPUTS: It is recommended that the output common or return be connected to Protective Earth in the end application.
The output is not acceptable for patient connection without additional isolation. The DC output is SELV under normal and
single fault conditions. Output #3 is isolated from Ground and may be referenced positive or negative.
41-34338-0001 Rev. G 11/30/05
clause 5 of IEC 60601-1)
(In accordance with sub-
Max Output Power at ambient of 50°C:
Max Output Current in table below is with Convection / 150 LFM airflow cooling except GLD140H which is convection
For all models, fan output is 12 V dc, 0.25 A max.
Minimum output current of 3 A is required on output #1 for proper regulation.
Maximum Operating Relative Humidity 96 %, no condensation.
Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of
power.
180 Watts maximum with cover/fan option or slotted cover with a minimum of 150 LFM airflow.
140 Watts maximum with no airflow and no cover.
only.
SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions
of the Low Voltage Directive 73/23/EEC.
Model
GLD140A
GLD140B
GLD140C
GLD140D
GLD140E
GLD140F
GLD140G
GLD140H
:
Volts
(5.1) Protection against electric shock = Class I
(5.2) Degree of protection against electric shock = Not acceptable for applied part without
additional isolation (contact factory for details)
(5.3) Protection against harmful ingress of water = Ordinary (no protection)
(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic mixture with
air, oxygen, or nitrous oxide. This evaluation is to be made on the end equipment by the OEM.
(5.6) Mode of operation = Continuous
Output #1
5
5
5
5
5
5
5
5
16 / 20 A
16 / 20 A
16 / 20 A
16 / 20 A
16 / 20 A
16 / 20 A
16 / 20 A
Current
6 A
Note 2
Volts
12
12
12
24
24
15
12
3.3
Output #2
INSTALLATION INSTRUCTIONS
10 / 12 A
Current
6 / 8 A
6 / 8 A
6 / 8 A
4 / 6 A
4 / 6 A
5 / 7 A
2.5 A
GLD140 SERIES
Volts
12
15
12
15
12
12
15
5
Output #3
Current
4 / 5 A
4 / 5 A
4 / 5 A
4 / 5 A
4 / 5 A
4 / 5 A
4 / 5 A
2 A
Volts
-12
-12
-15
-12
-15
-12
-12
-15
Output #4
0.75 / 1.2 A
0.75 / 1.2 A
0.75 / 1.2 A
0.75 / 1.2 A
0.75 / 1.2 A
0.75 / 1.2 A
0.75 / 1.2 A
Current
2 A
Page 1 of 2

Related parts for GLD140G

GLD140G Summary of contents

Page 1

... GLD140A 5 GLD140B 5 GLD140C 5 GLD140D 5 GLD140E 5 GLD140F 5 GLD140G 5 GLD140H 5 Notes: 1. For all models, fan output dc, 0.25 A max. 2. Minimum output current required on output #1 for proper regulation. 3. Maximum Operating Relative Humidity condensation. 4. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power ...

Page 2

GLD140 SERIES INSTALLATION INSTRUCTIONS OVERVOLTAGE PROTECTION: The output is monitored for an overvoltage condition. In some applications where an overvoltage condition could result in a hazard as defined in applicable safety standards, redundant or additional overvoltage protection may be required. ...