SE-1500-12 Mean Well, SE-1500-12 Datasheet
SE-1500-12
Specifications of SE-1500-12
Related parts for SE-1500-12
SE-1500-12 Summary of contents
Page 1
... SAFETY & WITHSTAND VOLTAGE I/P-O/P:3KVAC EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH MTBF 134.5K hrs min. OTHERS DIMENSION 278*177.8*63.5mm (L*W*H) 3.3Kg; 4pcs/14.2Kg/1.14CUFT PACKING NOTE SE-1500-12 SE-1500-15 12V 15V 125A 100A 0 ~ 125A 0 ~ 100A 1500W 1500W 150mVp-p 150mVp-p 10.8 ~ 13.5V 13.5 ~ 16.5V 2 ...
Page 2
... Case No.982A OUTPUT 16max. Assignment Mating Housing Terminal +S JST XHP JST SXH-001T RC- or equivalent or equivalent RC+ fosc : 65KHz RECTIFIERS & FILTER O.V.P. DETECTION CIRCUIT REMOTE CONTROL 190 200 230 INPUT VOLTAGE (VAC) 60Hz File Name:SE-1500-SPEC 2009-03- Unit: DC_OK RC 260 ...
Page 3
... DC_OK signal is a TTL level signal, referenced to pin2(DC_OK GND). "High" when PSU turns on. This pin connects to the negative terminal (-V). Return for DC_OK signal output. 2 GND Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair minimize noise pick-up effect. ...