Linear & Switching Power Supplies 55W 5V @ 11A

GPC55-5G

Manufacturer Part Number
GPC55-5G
Description
Linear & Switching Power Supplies 55W 5V @ 11A
Manufacturer
SL Power
Series
GPCr
Datasheet

Specifications of GPC55-5G

Product
Switching
Commercial/medical
Commercial
Output Power Rating
55 W
Input Voltage
85 VAC to 264 VAC
Number Of Outputs
1
Output Voltage (channel 1)
5 V
Output Current (channel 1)
11 A
Mounting Style
Chassis
Open Frame/enclosed
Open Frame
Output Type
Single Output
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Add “G” suffix to model to indicate RoHS compliant moel.
SL Power Electronics Corp.. 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 5/08.
Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
GPC55/GPM55 MECHANICAL SPECIFICATIONS
Commercial
Model
GPC55A
GPC55B
GPC55C
GPC55D
GPC55E
GPC55F
GPC55-5
GPC55-12
GPC55-15
GPC55-24
GPC55-28
GPC55-48
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
Medical
Model
GPM55A
GPM55B
GPM55C
GPM55D
GPM55E
GPM55F
GPM55-5
GPM55-12
GPM55-15
GPM55-24
GPM55-28
Output No.
OPERATING
See individual Specs -40 to +85°C
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
1
1
1
1
1
pk
rms’
0.003 g
2
/Hz
Output
+12 V
+12 V
+12 V
+15 V
+24 V
+12 V
+24 V
+15 V
+12 V
+15 V
-12 V
-12 V
-15 V
-12 V
-15 V
-15 V
+5 V
+5 V
+5 V
+5 V
+5 V
+5 V
12 V
15 V
24 V
28 V
48 V
-5 V
-5 V
5 V
NON-OPERATING
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
rms’
pk
0.026 g
2
/Hz
Minimum
Output
0.7 A
0.7 A
0.7 A
0.7 A
0.7 A
0.7 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
0 A
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
Maximun
Output
1.5 A
1.5 A
4.7 A
3.7 A
2.3 A
2.0 A
1.5 A
11 A
6 A
3 A
1 A
1 A
6 A
3 A
1 A
1 A
6 A
3 A
1 A
1 A
6 A
1 A
1 A
6 A
1 A
1 A
6 A
3 A
1 A
1 A
Output
Peak
1.2 A
1.2 A
1.2 A
1.2 A
1.2 A
1.2 A
1.2 A
1.2 A
1.2 A
1.2 A
1.2 A
5.8 A
4.7 A
2.9 A
2.4 A
1.5 A
14 A
5 A
8 A
5 A
8 A
5 A
8 A
5 A
8 A
5 A
8 A
8 A
5 A
11
Noise P-P
120 mV
120 mV
120 mV
120 mV
120 mV
150 mV
150 mV
240 mV
120 mV
120 mV
120 mV
150 mV
150 mV
120 mV
150 mV
150 mV
120 mV
150 mV
240 mV
280 mV
480 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
Regulation (A)
Total
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
3%
3%
2%
2%
2%
2%
2%
2%

Related parts for GPC55-5G