RSP-3000-12 Mean Well, RSP-3000-12 Datasheet

Linear & Switching Power Supplies 2400W 12V 200A ACTIVE PFC FUNCTION

RSP-3000-12

Manufacturer Part Number
RSP-3000-12
Description
Linear & Switching Power Supplies 2400W 12V 200A ACTIVE PFC FUNCTION
Manufacturer
Mean Well
Datasheet

Specifications of RSP-3000-12

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
AUXILIARY POWER(AUX)
REMOTE ON/OFF CONTROL
ALARM SIGNAL OUTPUT
OUTPUT VOLTAGE TRIM
CURRENT SHARING
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
3000W Single Output Power Supply
Note.3
Note.2
90
90
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
12V
200A
0 ~ 200A
2400W
150mVp-p
10.8 ~ 13.2V
1000ms, 80ms at full load
10ms at full load
180 ~ 264VAC
47 ~ 63Hz
0.95/230VAC at full load
20A/180VAC
RSP-3000-12
86%
60A/230VAC
<2.0mA / 240VAC
100 ~ 112% rated output power
User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover
13.8 ~ 16.8V
Protection type : Shut down o/p voltage, re-power on to recover
12V@0.1A(Only for Remote ON/OFF control)
Please see the Function Manual
Please see the Function Manual
2.4 ~ 13.2V
Please see the Function Manual
-20 ~ +70
20~90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
104.5K hrs min.
278*177.8*63.5mm (L*W*H)
4Kg; 4pcs/16Kg/1.89CUFT
UL60950-1, TUV EN60950-1 approved
Compliance to EN55022 (CISPR22)
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
1.0%
0.5%
0.5%
0.05%/
5 (12V), 110
5 (12V), 85
(0 ~ 50 )
(Refer to output load derating curve)
I/P-FG:1.5KVAC
16A/230VAC
MIL-HDBK-217F (25 )
254 ~ 370VDC
5 (24V), 75
5 (24V), 105
O/P-FG:0.5KVAC
5 (48V) (TSW2 : detect on heatsink of o/p diode)
5 (48V) (TSW1: detect on heatsink of power transistor)
24V
125A
0 ~ 125A
3000W
150mVp-p
22 ~ 28V
RSP-3000-24
28.8 ~ 33.6V
4.8 ~ 28V
90%
1.0%
0.5%
0.5%
R S P - 3 0 0 0
48V
62.5A
0 ~ 62.5A
3000W
200mVp-p
43 ~ 56V
90.5%
RSP-3000-48
57.6 ~ 67.2V
9.6 ~ 56V
1.0%
0.5%
0.5%
File Name:RSP-3000-SPEC 2010-10-18
s e r i e s

Related parts for RSP-3000-12

RSP-3000-12 Summary of contents

Page 1

... Single Output Power Supply SPECIFICATION MODEL RSP-3000-12 DC VOLTAGE 12V RATED CURRENT 200A CURRENT RANGE 0 ~ 200A RATED POWER 2400W RIPPLE & NOISE (max.) 150mVp-p Note.2 OUTPUT VOLTAGE ADJ. RANGE 10.8 ~ 13.2V VOLTAGE TOLERANCE 1.0% Note.3 LINE REGULATION 0.5% LOAD REGULATION 0.5% ...

Page 2

... HRS DF11-10DS HRS DF11-**SC or equivalent or equivalent AUX: Auxiliary Output OLP: OLP/OL-SD:OLP mode select PFC fosc : 88KHz PWM fosc : 100KHz +S RECTIFIERS +V & -V FILTER -S O.V.P. DETECTION CIRCUIT P OK REMOTE RC CONTROL CS RECTIFIERS AUX POWER & FILTER (12V/0.1A) File Name:RSP-3000-SPEC 2010-10- Unit:mm CN1 CN2 CN3 ...

Page 3

... Fig. 1.2(C) SW Open SW Close SW Close SW Open (B)Using internal 12V auxiliary output AUX 12V RC 12V typ. SW RCG AUXG AUX RCG AUXG Ta=25 185 190 195 200 210 220 230 240 250 INPUT VOLTAGE (V) 60Hz AUX 1K RC RCG SW AUXG File Name:RSP-3000-SPEC 2010-10- 264 ...

Page 4

... Fig. 3.2 Output voltage trimming Output of alarm(P OK2, TTL Signal) Low (0.5V max at 10mA) High or open (External applied voltage, 10mA max.) P OK2 R 0.1uF GND2 External voltage and R (The max. sink is 10mA and 30V) 100 100 120 OUTPUT VOLTAGE (%) File Name:RSP-3000-SPEC 2010-10- ...

Page 5

... OL-SD OLP Fig. 5.1 Remove the CN3 OLP Mode : constant current limiting +V CN1 + CN2 + CN1 + CN2 +V CN1 + CN2 OL-SD OLP Fig. 5.2 Insert the CN3 OLP Mode : constant current limiting with delay shutdown after 5 seconds Load -V File Name:RSP-3000-SPEC 2010-10- ...

Page 6

... Single Output Power Supply 6.Three Phase Connect FIG 220VAC SYSTEM (STANDARD MODEL FOR STOCK) FIG 220/380VAC SYSTEM FIG 190/110VAC SYSTEM FG1 FG2 FG3 (NC FG1 FG2 FG3 FG1 FG2 N2 N (N.C FG3 (NC File Name: RSP-3000-SPEC 2010-10-18 ...